System Registers - Default Factory State
The following table details the VN-200’s settings as it is delivered from the factory. These settings may
be restored by issuing a Restore Factory Settings command (Section 0) or by using the Restore Factory
Settings signal pins.
Table 40 – Factory Default Register Values
Settings Name
Default Factory Value
Serial Baud Rate
115200 (Both serial ports)
Async Data Output Frequency
40 Hz (Both serial ports)
Async Data Output Type
INS : INS Solution (Both serial ports)
Magnetic and Gravity Reference Vectors
+1.0e+0, +0.0e+0, +1.8e+0
+0.0e+0, +0.0e+0, -9.0
Reference Frame Rotation
1.0, 0.0, 0.0, 0.0, 1.0, 0.0, 0.0, 0.0, 1.0
Communication Protocol Control
0,0,0,0,1,0,1
Synchronization Control
3,0,0,0,6,1,0,100000000,0
GPS Antenna Offset
0,0,0