background image

VECTRONIC Aerospace 

Doc. No.: 

TT5 User’s Manual 

Date: 

05.06.2020 

 
 
 

This design is the property of VECTRONIC Aerospace GmbH. Unauthorized duplication or distribution to a third party is prohibited. 

 

 

9 /10 

 

 
 

4

 

Status Messages 

Every message that is sent by the trap transmitter is received by VECTRONIC Aerospace and 
forwarded  to  you  via  email.  Once  a  status  message  (trap  has  not  triggered)  is  received,  you 
will get an email like this if HTML is enabled in your mail application (actual appearance of 
the email might vary, depending on your mail application): 

 

Figure 5: Status email in HTML 

If display of HTML email is disabled, you will see 

VECTRONIC Aerospace 
Trap has NOT yet triggered. 
Trap ESN: 

0-367220 

Sequence number: 

258 

Estimated remaining lifetime:  13633 days 

 

In case of an alarm message (trap has triggered) you will get an email like this: 

 

Figure 6: Alarm email 

If display of HTML email is disabled in your mail application, you will see 

VECTRONIC Aerospace 
*** TRAP HAS TRIGGERED *** 
 
Trap ESN: 

0-368019 

Sequence number: 

259 

Time since triggering: 120 minutes 
Estimated remaining lifetime:  13632 days 

 

 

Summary of Contents for Globalstar TT5

Page 1: ...Project TT5 Globalstar Trap Transmitter Title User s Manual Document No TT5 User s Manual Version 1 Last Change 05 06 2020 ...

Page 2: ...This design is the property of VECTRONIC Aerospace GmbH Unauthorized duplication or distribution to a third party is prohibited 2 10 Name Date Signature Prepared by Christian Schütte 18 04 2011 Edited by Chris Samek 05 06 2020 Checked by Approved by Authorized by ...

Page 3: ...nual Date 05 06 2020 This design is the property of VECTRONIC Aerospace GmbH Unauthorized duplication or distribution to a third party is prohibited 3 10 DOCUMENT CHANGE RECORD Issue Date Item s Affected Description 1 05 06 2020 Initial Issue ...

Page 4: ...and by mode 5 Figure 2 Left The elongated magnet is inserted into the transmitter box and can be attached to the trap by a rope or wire If the trap is triggered the magnet has to be pulled out of the box by the rope to set off an alarm Right Triggered trap transmitter elongated magnet is removed from transmitter box 6 Figure 3 Example for triggering the trap A The trap is connected to the transmit...

Page 5: ...s you information about the ESN ID and CH ESN is the communication ID of the transmitter Write down this number as this will help you identify the transmitter once you receive status or alarm messages The ID is the serial number of the TT5 and can also be used to identify the transmitter CH is the transmission channel of the Globalstar transmitter Transmission channel is either A North America or ...

Page 6: ...o be pulled out of the box by the rope to set off an alarm Right Triggered trap transmitter elongated magnet is removed from transmitter box The magnet can be connected to the trap with a rope Make sure that the rope connecting the trap to the magnet is 1 stretched tightly enough to pull the magnet out of the box if the trap is triggered see Figure 3 2 can move freely and cannot be entangled when ...

Page 7: ...otherwise transmission performance might be degraded or even impossible To trigger the transmitter the magnet has to be pulled out of the transmitter box Make sure that the box is mounted in an angle that allows the magnet to be pulled out of the box and that nothing obstructs the path of the magnet or the rope 2 3 Resetting the trap After the trap has been triggered it is necessary to attach the ...

Page 8: ...r the magnet has been removed When the trigger magnet is removed i e the trap has been triggered the transmitter will switch to Alarm Mode 3 3 Alarm Mode In Alarm Mode the transmitter will send a status message every 30 minutes for 10 hours 20 messages in total indicating that the trap has been triggered and the transmitter will start counting the time since the trigger event These messages will b...

Page 9: ...ed in your mail application actual appearance of the email might vary depending on your mail application Figure 5 Status email in HTML If display of HTML email is disabled you will see VECTRONIC Aerospace Trap has NOT yet triggered Trap ESN 0 367220 Sequence number 258 Estimated remaining lifetime 13633 days In case of an alarm message trap has triggered you will get an email like this Figure 6 Al...

Page 10: ...ike this TRAP HAS TRIGGERED ESN 0 368019 Trigger is 120 minutes old 5 Lifetime calculation With each message you will receive the Estimated remaining lifetime The number of days given here is the number of days the Trap Transmitter would work in Stand by Mode Each sent message needs the same amount of energy as one day in Standby Mode As a result in Normal Mode Estimated remaining lifetime will re...

Reviews: