10
Power - On/Standby (1)
The POWER switch controls the AC power to the unit and is controllable in
all modes of operation. When the POWER switch is turned on, the following
occurs:
•
Power is applied to the controller board and to all the displays
on the display board. The test program is initiated.
•
After about six seconds the main contactor is energized. Each
power supply is checked. The letter “P” will appear on the
upper display of that power supply.
Source - On/Off (2)
The SOURCE switch applies power from the Cathode, Discharge, and
Neutralizer power supplies to the appropriate pins of the neutralizer con-
nectors (P33 and P32), located on the power supply’s rear panel.
•
The word SOURCE appears above the switch indicating the
SOURCE switch has been selected.
•
The SOURCE switch may be turned off in any mode.
•
While in Remote mode, the SOURCE switch may be turned on
through the remote device.
•
In any other mode, the SOURCE switch may be controlled
from the front panel.
Beam - On/Off (3)
The BEAM switch applies power from the Beam and Accelerator power sup-
plies to the appropriate pins of the source connector (P33) located on the
power supply’s rear panel.
•
The word BEAM appears above the switch indicating the
BEAM switch has been selected.
•
While in Manual, Local, and Local Restricted modes, the beam
may be turned on only if the source is already on.
•
The BEAM switch may be turned off in any mode.
•
While in Remote mode, the BEAM switch may be turned on
through the remote device.
•
In any other mode, the BEAM switch may be controlled from
the front panel.
Summary of Contents for MPS-3000 CE
Page 1: ...MPS 3000 CE Power Supply Technical Manual 425964...
Page 2: ...MPS 3000 CE Power Supply Technical Manual...
Page 90: ...86 Filament Cathode with Filament Neutralizer or PBN Option...
Page 91: ...87 Hollow Cathode and HCN 7 pin or 2 x 4 pin feedthrough...
Page 92: ...88 Hollow Cathode and Hollow Cathode Neut 6 pin feedthrough...
Page 93: ...89 Filament Cathode with Filament Neutralizer or PBN Option...
Page 94: ...90 3cm Source Filament Cathode and Filament Neutralizer...
Page 95: ...91 3cm Source Hollow Cathode and Hollow Cathode Neutralizer...