Appendix A
Upgrading IQ Control Box Software - Repeat For Each IQ Control Box
A-6
Disconnect, lock out, and tag power to the IQ Control Box at the panel be
-
fore starting these steps.
7. Disconnect power from the IQ Control Box.
8. Place the Bypass Jumper in the Normal Position.
Table A-2. Motor Type Programming
Number of
Code LED
Flashes
Switch Position
Manufacturer
Motor
1
2
3
4
5
1
OFF
OFF
OFF
OFF
OFF
FARADYNE
1/3 60 Hz
2
OFF
OFF
OFF
OFF
ON
3/4 60 Hz
3
OFF
OFF
OFF
ON
OFF
1.5 60 Hz
4
OFF
OFF
OFF
ON
ON
2.0 60 Hz
5
OFF
OFF
ON
OFF
OFF
X3
6
OFF
OFF
ON
OFF
ON
3/4 50 Hz
7
OFF
OFF
ON
ON
OFF
1.5 50 Hz
8
OFF
OFF
ON
ON
ON
2.0 50 Hz
9
OFF
ON
OFF
OFF
OFF
X4
10
ON
OFF
OFF
OFF
OFF
FRANKLIN
1/3 60 Hz
11
ON
OFF
OFF
OFF
ON
3/4 60 Hz
12
ON
OFF
OFF
ON
OFF
1.5 60 Hz
13
ON
OFF
OFF
ON
ON
2.0 60 Hz
14
ON
OFF
ON
OFF
OFF
X3
15
ON
OFF
ON
OFF
ON
3/4 50 Hz
16
ON
OFF
ON
ON
OFF
1.5 50 Hz
17
ON
OFF
ON
ON
ON
2.0 50 Hz
18
ON
ON
OFF
OFF
OFF
X4
SOLID
ANY OTHER SETTING
UNKNOWN
UNKNOWN