C&C Mode
C&C Mode Setup Categories
49
Idle State Safety Features
Two Idle State safety features (Stop Flow Timeouts) are built into the EMR4 system.
•
Pressing the START button puts the EMR4 into the Delivery State. If fuel flow is not detected within 1200
seconds (default), the delivery is terminated. The nozzle icon (Figure 1 on page 4) will begin blinking 30
seconds before delivery is terminated.
•
A second idle state occurs when flow is halted during a delivery. The user has 180 seconds (default) to push
the FINISH button to complete the delivery or the delivery is terminated.
These timeouts can be enabled or disabled by the Delivery Timeout feature (see Figure 47).
REPORT FORMATS
Figure 48 illustrates the Delivery Ticket and Shift Report Formats that are setup in C&C Mode. In this setup
selections can be made that determine which lines (printer labels) will print on Delivery Tickets and on Shift
Reports. Two formats each can be selected for Delivery Tickets and for Shift Reports.
To edit label content see Figure 32 on page 33.