Appendix A: Vendor Information – Veeder-Root
The ProtoNode provides capability to support any Veeder-Root serial command by defining customized map
descriptors for any command or data type. Refer to Appendix A-1 of the 577014-XXX Veeder Root Driver Manual.
Refer to Appendix A-10 of the 577014-XXX Veeder Root Driver Manual for instructions on using a Security Code
for the TLS communications port.
Interface To BACnet & Modbus Tables
An X in the BACnet Object ID or Modbus Register represents a one- or two-digit number that equals
the Node ID. In the Liquid Sensor X Fuel Alarm examples below, with a Node ID of 3, the X will be 3;
for a Node ID of 11, the X will be 11.
Table A-1. System Veeder-Root Interface Mappings to BACnet, Modbus and SNMP
Point Name
Node ID
BACnet Object ID (X002)
Modbus Register (10X02)
SNMP OID
(1.3.6.1.4.1.6347.0.XX1.2.0)
Sensor X Fuel Alarm
3
3
002
10
3
02
1.3.6.1.4.1.6347.0.
3
1.2.0
Sensor X Fuel Alarm
11
11
002
10
11
02
1.3.6.1.4.1.6347.0.
11
1.2.0
Point Name
BACnet
Object Type
BACnet
Object ID
Modbus
Register
SNMP OID
Unknown Device Address
AI
1
30001
1.3.6.1.4.1.6347.0.1.1.0
Unknown Alarm Category
AI
2
30002
1.3.6.1.4.1.6347.0.1.2.0
Unknown Alarm Type
AI
3
30003
1.3.6.1.4.1.6347.0.1.3.0
Printer out of Paper
BI
1
10001
1.3.6.1.4.1.6347.0.1.4.0
Printer Error
BI
2
10002
1.3.6.1.4.1.6347.0.1.5.0
EEPROM Configuration Error
BI
3
10003
1.3.6.1.4.1.6347.0.1.6.0
Battery Off
BI
4
10004
1.3.6.1.4.1.6347.0.1.7.0
Too Many Tanks
BI
5
10005
1.3.6.1.4.1.6347.0.1.8.0
System Security Warning
BI
6
10006
1.3.6.1.4.1.6347.0.1.9.0
ROM Revision Warning
BI
7
10007
1.3.6.1.4.1.6347.0.1.10.0
Remote Display Communications Error
BI
8
10008
1.3.6.1.4.1.6347.0.1.11.0
Autodial Error
BI
9
10009
1.3.6.1.4.1.6347.0.1.12.0
Software Module Warning
BI
10
10010
1.3.6.1.4.1.6347.0.1.13.0
Tank Test Shutdown Warning
BI
11
10011
1.3.6.1.4.1.6347.0.1.14.0
Protective Cover Alarm
BI
12
10012
1.3.6.1.4.1.6347.0.1.15.0
BIR Shift Close Pending
BI
13
10013
1.3.6.1.4.1.6347.0.1.16.0
BIR Daily Close Pending
BI
14
10014
1.3.6.1.4.1.6347.0.1.17.0
PC(H8) Revision Warning
BI
15
10015
1.3.6.1.4.1.6347.0.1.18.0
System Self Test Error
BI
16
10016
1.3.6.1.4.1.6347.0.1.19.0
System Clock Incorrect Warning
BI
17
10017
1.3.6.1.4.1.6347.0.1.20.0
System Device Poll Timeout
BI
18
10018
1.3.6.1.4.1.6347.0.1.21.0
Maintenance Tracker NVMem
BI
19
10019
1.3.6.1.4.1.6347.0.1.22.0
Maintenance Tracker Communication Module
BI
20
10020
1.3.6.1.4.1.6347.0.1.23.0
Database Error
BI
21
10021
1.3.6.1.4.1.6347.0.1.24.0
File System Error
BI
22
10022
1.3.6.1.4.1.6347.0.1.25.0
BIR Status Warning
BI
23
10023
1.3.6.1.4.1.6347.0.1.26.0
VR Bus Power Outage Warning
BI
24
10024
1.3.6.1.4.1.6347.0.1.27.0
Software Upgrade Failure Alarm
BI
25
10025
1.3.6.1.4.1.6347.0.1.28.0
iButton Fault Warning
BI
26
10026
1.3.6.1.4.1.6347.0.1.29.0
iButton Fault Alarm
BI
27
10027
1.3.6.1.4.1.6347.0.1.30.0
Version Upgrade Available
BI
28
10028
1.3.6.1.4.1.6347.0.1.31.0
Expansion Box Unsupported
BI
29
10029
1.3.6.1.4.1.6347.0.1.32.0
NOTICE