background image

Notice

Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of
merchantability and fitness for a particular purpose.

Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages in connection with the
furnishing, performance, or use of this publication.

Veeder-Root reserves the right to change system options or features, or the information contained in this publication.

This publication contains proprietary information which is protected by copyright. All rights reserved. No part of this publication
may be photocopied, reproduced, or translated to another language without the prior written consent of Veeder-Root.

Contact TLS Systems Technical Support for additional troubleshooting information at 800-323-1799.

DAMAGE CLAIMS / LOST EQUIPMENT

Thoroughly examine all components and units as soon as they are received. If any cartons are damaged or missing, write a
complete and detailed description of the damage or shortage on the face of the freight bill. The carrier's agent must verify the
inspection and sign the description. Refuse only the damaged product, not the entire shipment.

Veeder-Root must be notified of any damages and/or shortages within 30 days of receipt of the shipment, as stated in our Terms
and Conditions. 

VEEDER-ROOT’S PREFERRED CARRIER

1.

Contact Veeder-Root Customer Service at 800-873-3313 with the specific part numbers and quantities that were missing
or received damaged.

2.

 Fax signed Bill of Lading (BOL) to Veeder-Root Customer Service at 800-234-5350.

3.

Veeder-Root will file the claim with the carrier and replace the damaged/missing product at no charge to the customer.
Customer Service will work with production facility to have the replacement product shipped as soon as possible.

CUSTOMER’S PREFERRED CARRIER

1.

It is the customer’s responsibility to file a claim with their carrier.

2.

Customer may submit a replacement purchase order. Customer is responsible for all charges and freight associated with
replacement order. Customer Service will work with production facility to have the replacement product shipped as soon as
possible.

3.

If “lost” equipment is delivered at a later date and is not needed, Veeder-Root will allow a Return to Stock without a restocking
fee.

4.

Veeder-Root will NOT be responsible for any compensation when a customer chooses their own carrier. 

RETURN SHIPPING

For the parts return procedure, please follow the appropriate instructions in the "General Returned Goods Policy” pages in the
"Policies and Literature" section of the Veeder-Root 

North American Environmental Products

 price list. Veeder-Root will not

accept any return product without a Return Goods Authorization (RGA) number clearly printed on the outside of the package.

 ©Veeder-Root 2014. All rights reserved

.

Summary of Contents for TLS-450PLUS

Page 1: ...Manual No 577014 078 Revision A Hardware Replacement Guide TLS 450PLUS Console...

Page 2: ...r Terms and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Contact Veeder Root Customer Service at 800 873 3313 with the specific part numbers and quantities that were missing or received damaged 2 Fax...

Page 3: ...PLUS Console Doors 4 Figure 4 CPU board 5 Figure 5 Remove Display Cables From CPU Board 6 Figure 6 Remove Ground Wire From Ack Switch Display Door 7 Figure 7 Remove Top And Bottom Optional Display Doo...

Page 4: ...perations training system tests troubleshooting and servicing for all Veeder Root Series Tank Monitoring Systems including Line Leak Detection In addition Contractors with the following sub certificat...

Page 5: ...RNING Heed the adjacent instructions to avoid damage to equipment property environment or personal injury STATIC SENSITIVE COMPONENTS Wear grounded anti static wrist strap before handling the printed...

Page 6: ...down arrow in the Backup Destination field to select the Backup thumb drive inserted in Step 1 then follow the on screen instructions to backup TLS 450PLUS console data Figure 2 DB Backup Screen 3 Tu...

Page 7: ...or 1a pointer up 90 from the connector s fixed base and slide cable end out Legend For Figure 3 Item Description Item Description 1 Left blank door or optional printer door 4 Remove the top and bottom...

Page 8: ...nnector optional dis play 3 USB Type A connectors 2 12 Features iButton 4 Ethernet RJ 45 connectors 3 13 Backup Battery 5 USB 0 1 pitch header connectors 2 14 Configuration DIP switches 6 Display cabl...

Page 9: ...Off Power 6 3 Remove the LED Back light cable pointer 2 from CPU board connector see Figure 5 Figure 5 Remove Display Cables From CPU Board 4 Remove the Ground wire at the top of the door see Figure 6...

Page 10: ...r 7 5 Remove the TLS 450PLUS Ack Switch Panel Display door by removing the top and bottom hinge shoulder screws see Figure 7 Figure 7 Remove Top And Bottom Optional Display Door Hinge Screws 6 Replace...

Page 11: ...T15 ground clamp screw securing the ground wire at the top of the Printer door and slide it free of the clamp see Figure 8 Figure 8 Removing Printer Door Ground Wire 5 If a printer is installed unplug...

Page 12: ...2 of the section entitled Replacing Left Door With Or Without Printer on page 8 3 Remove the two T15 screws from the AC Channel cover and put the cover and screws aside see Figure 10 Figure 10 Remove...

Page 13: ...connectors Lift the AC Input Filter out of the console Remove the two T 15 screws that secure the AC Input board to the AC input board bracket Place fingers under the AC Input board near each of the...

Page 14: ...s identified by item 3 in Figure 12 9 Disconnect the printer power cable from the Power Supply board connector J1 10 Lift the board out of the console by its edges since there is still undischarged hi...

Page 15: ...y board With the handle item 3 of Figure 11 of the AC Input Filter against the left side of the console housing line up the two AC Input Filter bottom connectors over the two female connectors items 4...

Page 16: ...For technical support sales or other assistance please visit www veeder com...

Reviews: