This manual contains instructions for replacing the following TLS-450PLUS console components: 

• Display door assembly (P/N 330020-772)
• Acknowledge (Ack) Switch Panel door assembly (P/N 330020-774)
• Printer door assembly (P/N 330020-777)
• Non-printer (blank) door assembly (P/N 330020-775)
• Power supply (P/N 330020-623)

For troubleshooting information, see 577014-078. 

Contractor Certification Requirements

Veeder-Root requires the following minimum training certifications for contractors who will install and setup the 
equipment discussed in this manual:

Installer Certification (Level 1):

 Contractors holding valid Installer Certification are approved to perform wiring 

and conduit routing; equipment mounting; probe, sensor and carbon canister vapor polisher installation; wireless 
equipment installation; tank and line preparation; and line leak detector installation.

Technician Certification (Level 2/3):

 Contractors holding valid Technician Certifications are approved to 

perform installation checkout, startup, programming and operations training, system tests, troubleshooting and 
servicing for all Veeder-Root Series Tank Monitoring Systems, including Line Leak Detection. In addition, 
Contractors with the following sub-certification designations are approved to perform installation checkout, startup, 
programming, system tests, troubleshooting, service techniques and operations training on the designated system. 

• Wireless 2
• Tall Tank

VR Vapor Products Certification:

 Contractors holding a certification with the following designations are 

approved to perform installation checkout, startup, programming, system tests, troubleshooting, service 
techniques and operations training on the designated system. ISD – In Station Diagnostics

• PMC – Pressure Management Control
• CCVP - Veeder-Root Vapor Polisher
• Wireless – ISD/PMC Wireless
• A current Veeder-Root Technician Certification is a prerequisite for the VR Vapor Products course. 

Warranty Registrations

 may only be submitted by selected Distributors.

Safety Precautions

The following safety symbols may be used throughout this manual to alert you to important safety hazards and 
precautions

EXPLOSIVE

Fuels and their vapors are extremely explosive if ignited.

FLAMMABLE

Fuels and their vapors are extremely flammable.

Summary of Contents for TLS-450PLUS

Page 1: ...Manual No 577014 078 Revision A Hardware Replacement Guide TLS 450PLUS Console...

Page 2: ...r Terms and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Contact Veeder Root Customer Service at 800 873 3313 with the specific part numbers and quantities that were missing or received damaged 2 Fax...

Page 3: ...PLUS Console Doors 4 Figure 4 CPU board 5 Figure 5 Remove Display Cables From CPU Board 6 Figure 6 Remove Ground Wire From Ack Switch Display Door 7 Figure 7 Remove Top And Bottom Optional Display Doo...

Page 4: ...perations training system tests troubleshooting and servicing for all Veeder Root Series Tank Monitoring Systems including Line Leak Detection In addition Contractors with the following sub certificat...

Page 5: ...RNING Heed the adjacent instructions to avoid damage to equipment property environment or personal injury STATIC SENSITIVE COMPONENTS Wear grounded anti static wrist strap before handling the printed...

Page 6: ...down arrow in the Backup Destination field to select the Backup thumb drive inserted in Step 1 then follow the on screen instructions to backup TLS 450PLUS console data Figure 2 DB Backup Screen 3 Tu...

Page 7: ...or 1a pointer up 90 from the connector s fixed base and slide cable end out Legend For Figure 3 Item Description Item Description 1 Left blank door or optional printer door 4 Remove the top and bottom...

Page 8: ...nnector optional dis play 3 USB Type A connectors 2 12 Features iButton 4 Ethernet RJ 45 connectors 3 13 Backup Battery 5 USB 0 1 pitch header connectors 2 14 Configuration DIP switches 6 Display cabl...

Page 9: ...Off Power 6 3 Remove the LED Back light cable pointer 2 from CPU board connector see Figure 5 Figure 5 Remove Display Cables From CPU Board 4 Remove the Ground wire at the top of the door see Figure 6...

Page 10: ...r 7 5 Remove the TLS 450PLUS Ack Switch Panel Display door by removing the top and bottom hinge shoulder screws see Figure 7 Figure 7 Remove Top And Bottom Optional Display Door Hinge Screws 6 Replace...

Page 11: ...T15 ground clamp screw securing the ground wire at the top of the Printer door and slide it free of the clamp see Figure 8 Figure 8 Removing Printer Door Ground Wire 5 If a printer is installed unplug...

Page 12: ...2 of the section entitled Replacing Left Door With Or Without Printer on page 8 3 Remove the two T15 screws from the AC Channel cover and put the cover and screws aside see Figure 10 Figure 10 Remove...

Page 13: ...connectors Lift the AC Input Filter out of the console Remove the two T 15 screws that secure the AC Input board to the AC input board bracket Place fingers under the AC Input board near each of the...

Page 14: ...s identified by item 3 in Figure 12 9 Disconnect the printer power cable from the Power Supply board connector J1 10 Lift the board out of the console by its edges since there is still undischarged hi...

Page 15: ...y board With the handle item 3 of Figure 11 of the AC Input Filter against the left side of the console housing line up the two AC Input Filter bottom connectors over the two female connectors items 4...

Page 16: ...For technical support sales or other assistance please visit www veeder com...

Reviews: