Site Prep - International Installations
Mounting the TLS-IB
2-6
Mounting the TLS-IB
Install the TLS-IB fastening devices to the mounting surface using the hole pattern 170 x 145mm (6.7 x 5.7 inches)
shown in Figure 2-3. Mounting screws up to 4.7mm (3/16-inch) diameter may be used.
Mount the TLS-IB to the mounting surface using the four mounting flanges on the back of the unit. Install ducting
or conduit between the TLS-IB and the power panel. Figure 2-3 shows the three designated knockouts (one each
on top, left side, and bottom) through which power wiring can safely enter the TLS-IB.
Figure 2-3. TLS-IB Dimensions And Designated Conduit Knockouts
0.34'' (8,6) typ.
0.34'' (8,6) typ.
7.4" (188)
6.4''
(163)
5.7''
(145)
2" (50)
5.3'' (135)
1.24''
(31)
5.3'' (135)
0.54" inside (M12 conduit),
1/2'' I.P.S. (International Pipe Size) outside (PG7 conduit)
knockouts 4 places - bottom (2), left side (1), and top (1)
1/2", 3/4'', & 1'' I.P.S.
conduit knockout pattern (2 places)