background image

Introduction

A new standard of performance and functionality in a compact preset

counter. The V454502 Dual Preset Counter offers a pre-settable

counter with full calibration for a variety of applications.
The bright red LED display provides simultaneous count and preset

indication. The use of annunciators and simple key sequences makes

operator changes quick and easy. A variety of count sources are

accommodated, including relay and pushbutton contacts, photocells

and proximity switches and uni- or bi-directional incremental encoders. 

The open collector output can interface to light duty devices and the

relay contacts offer heavy duty load switching.
Set-up and installation are simplified

through

front panel entry of configuration

parameters

and a unique “no tools required” panel

mounting bracket.
The V454500 family of preset counters

combines state-of-the-art circuitry and

electronic assembly techniques with an

ergonomic package design that results

in the most cost-effective ,

high-performance counter value

on the market.

Features

*

Dual four-digit displays for Count 

and Preset values

*

10kHz count speed

*

Add/Subtract or bi-directional

count inputs

*

Digital calibrator and

programmable decimal point

*

Accepts current sinking or

sourcing devices

*

Key reset, remote reset and auto

reset modes

*

Reset to zero or preset number

*

Relay (SPDT) and open collector

outputs

*

Accessory sensor power supply

*

Universal 90 - 264V AC power

requirements

*

NEMA 4/IP65 sealed front panel

*

Designed to comply with

EN50081 and EN50082 EMC

specifications

Index

Overview

Construction

Page 2

Installation

Wiring

Page 3

Panel Mounting

Page 4

Operation

Front Panel

Page 5

Programming

Viewing Preset Value

Page 6

Changing Preset Value

Page 6

Program Mode

Page 7

Configuration Mode

Page 8

Appendix A - Specifications Page 9
Order Codes

Page 12

Summary of Contents for V454502

Page 1: ...e V454500 family of preset counters combines state of the art circuitry and electronic assembly techniques with an ergonomic package design that results in the most cost effective high performance counter value on the market Features Dual four digit displays for Count and Preset values 10kHz count speed Add Subtract or bi directional count inputs Digital calibrator and programmable decimal point A...

Page 2: ...us display of Count and Preset data Red LED display Annunciators show input display and output status Ergonomic Keypad Simple key sequences to view and edit Presets Front Panel Reset key can be disabled Front Panel Seal NEMA 4 IP65 rated when installed with panel mount gasket supplied Rear Terminal Connections Top of Counter ...

Page 3: ... Current Sinking NPN Count Inputs Connect Add count input to Terminal 2 A and or Subtract count input to Terminal 3 B see below In Configuration Mode set PuLL parameter to YES and for Add Subtract operation set InPu parameter to A B NPN Open Collector Contact Closure Current Sink or Line Driver Bi directional Quadrature Inputs Connect Quadrature Encoder to V Terminal 1 A input Terminal 2 B input T...

Page 4: ... out from the front of the mounting panel and hold the Counter lightly in position against the panel Ensure that the panel gasket is not distorted and that the Controller is positioned squarely against the mounting panel Apply pressure to the front panel bezel only Slide the mounting bracket in place see right and push it forward until it is firmly in contact with the rear face of the mounting pan...

Page 5: ...to select a parameter for editing left most digit will start to flash and to move between the digits Once the proper digit is selected flashing with the Next key its value can be altered through use of the Down key Program Mode Used to select a parameter for editing left most digit will start to flash and to move between the digits Once the proper digit is selected flashing with the Next key its v...

Page 6: ...he changes the display will stop flashing IMPORTANT You must press the ENT key within 15 seconds of the last keypress when entering a new value otherwise the new value will be discarded and the old value will be retained NOTE To abort an edit operation before the new value is confirmed press the Down and Next keys together WARNING Caution should be observed if it is necessary to change the preset ...

Page 7: ...her Preset value as selected press Next key to enter Edit Mode digits will flash use Next key to select each digit to be adjusted and adjust digit value using Down key When adjustment is complete press ENT key to exit Edit Mode digits will become static 2 To adjust decimal point position select that parameter press Next key to enter Edit Mode then use Next key to position decimal point Press ENT k...

Page 8: ...to scroll through the available settings When the desired setting is shown press the ENT key The Configuration Mode parameters in order of appearance are LOCK STRATEGY None No security all parameters available through regular methods of access Preset Lock Preset 1 and Preset 2 become Read Only Partial Lock Output ON times are Read Only Both Operator Mode parameters and Output ON times are Read Onl...

Page 9: ...sitive Program Mode Terminal 6 level sensitive Input Voltage High 3 0V or open Low 2 0V Input Impedance 4 7kΩ to V Input Response 25 0ms Max 30V DC Front Panel Keys Type Mechanical switches under sealed membrane overlay Display Type LED red 4 digit Height Upper 0 4 10mm Lower 0 3 7mm Security Preset data can be protected selectable in Configuration Mode Program data is accessible only if the PGM i...

Page 10: ...10 N O T E S ...

Page 11: ...11 N O T E S ...

Page 12: ...hausen ADF Tel 49 71589003 0 Fax 49 71589003 32 In Brazil Veeder Root do Brasil Rua Ado Benatti No 92 Caixa Postal 8343 CEP 05037 010 São Paulo Tel 55 118612155 Fax 55 118611982 1675 N Delany Road Gurnee IL 60031 1282 Tel 708 662 2666 This instrument is warranted to be free from defects in workmanship and material for a period of three years from the date of despatch In the unlikely event of a fau...

Reviews: