To enter Configuration Mode,
power-down the Counter and
remove it from its housing. Change
the position of the lnk jumper on
the CPU PCB (the actual position is
irrelevant, as long as the position is
changed). Replace the Counter in
its housing and power-up. The PGM
indicator will flash whilst the
Counter is in Configuration Mode.
To exit Configuration Mode, either momentarily remove power from the Counter
or press and hold down the
RST
key for at least two seconds.
To edit a parameter, use the Down key to step through the parameters; when the desired
parameter description is shown in the upper display, press the Next key to enter Edit Mode and
to scroll through the available settings. When the desired setting is shown, press the
ENT
key.
The Configuration Mode parameters, in order of appearance, are:
LOCK STRATEGY:
None
= No security; all parameters available through regular methods of access
Preset Lock
= Preset 1 and Preset 2 become Read Only
Partial Lock
= Output ON times are Read Only
Both
= Operator Mode parameters and Output ON times are Read Only.
Parameter
Counter Speed
Input Operation
Panel Reset Key
Auto Reset
Input Pull-Ups
Count Direction
Lock Strategy
Parameter
Description
(Upper Display)
Available Settings
Down key steps
through parameters
Counter
(Top view)
S E T U P
None
Preset
Lock
Partial
Program
Lock
Preset &
Program
Lock
Enable
Disable
Enable
Disable
Yes
(current-sinking
No
(current-sourcing
Up-countin
Down-countin
20Hz
200Hz
10kHz
A-B
(Add/Subtract)
Quadrature
(bi-directional)