ALARM SCREEN

Under no circumstances shall Veethree or any of its subsidiary companies 

accept liability for any loss of data, income, incidental damage, or conse-

quential losses incurred as a result of the use of the product, howsoever 

caused when used as a monitor for electronically controlled engines/trans-

mission or other systems.

Veethree operates a policy of continuous improvement. Veethree reserves 

the right to alter and improve the Veethree M2 displays and software with-

out prior notice.

CE EMC Directive 2004/108/EC

This product has been designed to be compliant with this directive. Compli-

ance can only be ensured by correct installation.

Summary of Contents for M2

Page 1: ...VEETHREE M2 With Veethree Engine Monitor Software ...

Page 2: ...latform Veethree M2 Connection Data Typical J1939 Wiring Topology Veethree M2 Installation Maintenance and Troubleshooting Home Screen Alarms Screen Main Menu Glossary Important Safety Information 3 4 5 6 7 9 10 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 2 ...

Page 3: ...mpatible engine transmission data Please read through the guide before use The VEM software creates graphical instrument clusters to display parame ters and alarms providing users with a time saving solution for introducing equipment incorporating higher degrees of electronic display We hope that you will be pleased with this product and that you will have many years of trouble free operation If y...

Page 4: ...ailable on the latest generation of electronically controlled systems The display offers 4 soft keys 128 x 64 pixel display area and 4 warning lights to signify engine fault failure It offers a Deutsch connector interface and a Mini USB port Fully sealed to IP 66 front and IP 67 back with Deutsch connector and rubber USB port plug inserted ...

Page 5: ...ctor on the rear of the display wired as shown see pin out diagram 1 2 3 4 5 6 1 2 3 4 5 6 Power Power CAN H CAN L Alarm Output AN Analog Input Ground and power 10 32VDC Supply should be protected by 500mA rated circuit breaker fuse Low Side Relay Switch to Ground Primary CAN Data Low Primary CAN Data High ...

Page 6: ... it is critical to use twisted shielded pair with a drain wire max length 40m terminated with 120 ohm resistors at each end In addition all stubs should not exceed 1m in length and a maximum of 30 nodes Stub Max length 1m Node 30 max Termination Resistor 120 ohm Backbone Max length 40m Veethree M2 Display Engine and or Transmission Termination Resistor 120 ohm ...

Page 7: ...ble connections This is to ensure that the cables are not unduly stressed and for ventilation Leave sufficient cable so that the unit may be removed for servicing Cut a 2 inch 51 mm hole Screw the studs into rear case Place the Veethree M2 display in position use the mounting bracket and thumb nuts to secure the unit The thumb nuts should only be hand tight Connect the Deutsch mating part into the...

Page 8: ...8 Unit mounting method Thumb Nuts Veethree M2 display Panel Bracket Studs ...

Page 9: ...wing diagnostics Unit does not power up Unit fails to display any data Unit displays random data Ensure connections to unit are correct Ensure power source is present Ensure connections to unit are correct Ensure data source is broadcasting data Ensure source address in the display matches source data being provided by the engine and or transmission Ensure the J1939 backbone is connected and termi...

Page 10: ...ing Key 1 repeatedly will cycle through available quad screens 4 screen max Key 2 is a dual gauge view pressing Key 2 repeatedly will cycle through available dual screens 4 screen max Key 3 is a single gauge view pressing Key 3 repeatedly will cycle through available single screens 4 screen max NOTE Number of available screens can be adjusted to 2 3 or 4 screens for each option ...

Page 11: ... Screen Dual Screen Single Screen Once the contrast changes use appropriate keys to change available infor mation Key highlights the data to be changed Key selects previous parameter Key selects next parameter Key exits adjust screen auto timeout approx 30 sec All available screens can be adjusted in this manner NOTE Bar graph is only available on the dual and single screens both the minimum and m...

Page 12: ...onnected Check Engine Alarm will sound along with Orange LED s Stop Engine Alarm will sound along with Red LED s To acknowledge the alarm press Key 4 to access alarm screen and then Key 3 to silence the alarm Pressing Key 4 again will exit alarm screen The alarm icons and LEDs will continue to flash until the alarm condition is resolved and alarm clear command is received from the engine and or tr...

Page 13: ... light contrast and button back light Settings Language and Key Tone options can be found here Protected Settings To access Protected Settings use PIN 1234 In the Pro tected Settings the user can change the units access Demo Mode J1939 settings Service Hours IO Setup Restore Defaults select Max Quad Dual and Single screens Diagnostics Used to access Data Viewer and CAN Diagnostics About Displays s...

Page 14: ...Controller Area Network also referred to as CAN bus serial communication protocol for automotive use Intelligent CAN compatible LCD display module Veethree Engine Monitor Liquid Crystal Display Push button keys whose function changes according to use ...

Page 15: ...ct howsoever caused when used as a monitor for electronically controlled engines trans mission or other systems Veethree operates a policy of continuous improvement Veethree reserves the right to alter and improve the Veethree M2 displays and software with out prior notice CE EMC Directive 2004 108 EC This product has been designed to be compliant with this directive Compli ance can only be ensure...

Page 16: ...three Electronics and Marine LLC 2050 47th Terrace East Bradenton Florida 34203 USA www veethree com 1 941 536 7775 Fax 1 941 755 1222 70617 Rev 3 VEETHREE M2 Display With Veethree Engine Monitor Software ...