DOC. NO. 5956.6K6.00
P. 14 / 28
8.2
Read Only Parameters
8.3
Communication and HACCP
Parameters
Sym.
Parameter Description
Unit
Min
Max
Factory
Default
Main Board Firmware Release
-
-
-
-
Water softener board software version. (only for dishwashers with
incorporated continuous water softener).
-
-
-
-
Active column: indicates through which of the two continuous
water softener columns boiler filling is being carried out: 0 = col-
umn A and 1 = column B (only for dishwashers with incorporated
continuous water softener).
-
-
-
-
When
message appears, the parameter value becomes 3.
After maintenance, to clear
message, insert 0.
-
-
-
-
When
alarm appears, the machine is frozen and this
parameter is 3.
After maintenance (see alarm codes document), insert 0 to ena-
ble the machine.
-
-
-
-
This alarm appears in case of malfunctioning in the continuous
water softener. To facilitate fault-finding, see par. In the case of a
shorted probe error (C 5, C 7 e C11), the displayed temperature is
210°F..
-
-
-
-
Sym.
Parameter Description
Unit
Min
Max
Factory
Default
Serial Device
0 = 8N1
1 = PC connection (DAAS 8E1)
7 = HACCP network (ECAP 8E1+LK485) (LK485 board is nec-
essary)
9 = Dishwashers with incorporated continuous water softener
16 = HACCP printer (8N1)
32 = MODEM GSM (DAAS 8N1)
33 = MODEM GSM (DAAS 8E1)
48 = Hyper Terminal (8N1)
-
0
63
1
Address.
This parameter specifies the address of the appliance into the
‘HACCP_network’.
Works only if ‘HACCP network’ is selected (see above parameter).
-
0
255
1
Print parameter table.
-
0
1
1
HACCP ‘Basic’ (printer)
Boiler temperature: high limit.
[°F]
113
203
194
HACCP ‘Basic’ (printer)
Boiler temperature: gap below high limit.
[°F]
32
68
50
HACCP ‘Basic’ (printer)
Tank temperature: high limit.
[°F]
95
167
154
HACCP ‘Basic’ (printer)
Tank temperature: gap below high limit.
[°F]
32
68
50