DOC. NO. 5956.6K6.00
P. 23 / 28
12 USER INTERFACE AND MAIN BOARD CONNECTORS
12.1 MAIN MALFUNCTIONS NOT DUE TO THE MAIN BOARD
12.2 CONNECTORS LAYOUT
KEY
C
N1
Rinse pump/wash pump/solenoid valve outputs
CN2
Pressure/atmospheric dishwasher solenoid valve connection
CN3
ECOTEMP transformer and detergent/rinse aid dispenser outputs
CN5
Tank/boiler temperature sensor inputs
CN8
Energy peak controller input
CN12
User interface inputs/outputs
CN15
Overflow/tank level/board feed input
CN16
User interface inputs/outputs and hood/door sensor input
CN17
Door microswitch connection
The display shows
with door/hood closed
Check door/hood micro/sensor
No cycle starts
Check the user interface buttons (have they remained
pressed? etc.)
A cycle fails to start
Is a user interface button extension missing?
After replacing the main board only the 3
rd
cycle starts
The main board is still configured for LS5/WT4.
Cycle time longer than that foreseen
Does the boiler work?
Is the feed water at 50°C?
Noisy wash pump (only on HT and PP versions)
Check the current for single phase during operation.
LAYOUT 9
VDU
3
0
ONLY
W
S