DOC. NO. 5956.6K6.00
P. 8 / 28
6 TEMPERATURE SETTING
In this paragraph is explained how to change temperature thresholds and all parameters related to boiler and
tank
.
6.1
Factory Parameters
Fig. 18 USER setting mode
(press for 5s).
Fig. 19 Next Family
Fig. 20 Counters Fam.:
ENTER
Fig. 21 CYCLES
Fig. 22 Thousand.
Fig. 23 Units.
Fig. 24 Next counter.
TANK
BOILER
GEn
1
2
3
TANK
BOILER
GEn
1
2
3
TANK
BOILER
Cnt
1
2
3
Fi
g
.1
8
Fi
g
.19
Fi
g
.20
CYC
010
042
1
2
3
cYc
1
2
3
Sym.
Parameter Description
Unit
Min
Max
Factory
Default
Boiler Temperature: THRESHOLD.
When boiler temperature reaches this value, heaters switch off.
[
°
F]
113
203
172
Boiler Temperature HISTERESIS, (represent dead band).
Heater switch on if boiler temperature is below:
-
[
°
F]
35
50
35
Boiler Temperature: HIGH LIMIT.
When boiler temperature reaches this value
alarm appears.
Put 0 to disable
alarm.
[
°
F]
32
208
204
Boiler Temperature: LOW LIMIT.
During boiler warm-up, temperature must increase at least
°C
otherwise
warning appears.
Put 0 to disable
warning.
[
°
F]
32
50
34