6 CONFIGURATION MODE
Configuration may be performed manually from the front panel or via the Web Browser interface. See section 4.7
for Web Browser operation.
During boot-up (during power-up or after selecting Factory Defaults) the unit goes through a short process when
the buttons are not accessible.
Since multiple switches may be used in an installation, each output port must have a Switch
Address for the
controller to know which switch to control.
Use the Left or Right arrow keys to select the Switch Address screen for Port A and Port B. Press ENTER and
use the Left and Right arrow keys to navigate from Port A to B and vice versa. Use the Up and Down arrow keys
to increment or decrement the port numbers for each output port.
Note: If a switch is used as a combiner for other switches it should be configured as port 1.
In addition, each port must be configured to match its controller. Use the Left or Right arrow keys to select Setup
mode for Port A or Port B.
Or
Press the Enter button to select one of the above and to display the current setting for that Port. Once Config
-
uration Mode has been selected, the AT1700 displays the communicate information for that port. Each Port’s
configuration is independent,
Use the Left and Right arrow keys to navigate to the desired parameter to change and use the Up and Down
arrows to change the setting.
Note: The Baud rate must match the controller device. Typically the highest Baud rate setting
is the most preferred.
There are two Protocol modes, Long and Short. Similarly, select the appropriate Protocol for the controller. Typi
-
cally Long Protocol for PC and AT2500s as controllers and Short for CaLan 3010 applications.