Only trained and qualified personnel should be allowed to install, replace, or ser
-
vice this equipment.
Improper or unsafe use can cause physical harm and damage equipment.
1.0 InTRoduCTIon
The CX180F is a rack mount monitoring system to check the performance of analog and digital channels being
transmitted downstream or toward customers across a CATV HFC network. Equipped with key signal parameters
including level, BER, MER, and Constellation are measured continuously and non-intrusively. Advanced spec-
trum analysis scans the entire operating frequency band, detects ingress which can lead to signal impairment
and/or failure. The ReVeal CX180F controller/server package that forms an integral part of the system, continu-
ously checks for signal values that exceed user defined thresholds. Out of tolerance parameters trigger alarms
which inform and alert the headend operator of problematic links and service.
The CX180R is a rack mount headend system that completes the requirement of DOCSIS 3.0 deployment
where higher QAM on the return path becomes necessary and mandatory. The compact 1U rack mount chassis
supports simultaneous and continuous ingress scanning of all 10 ports at a fast sweep rate of 200ms and dual
ports are available for return path spectrum, QAM, MER, BER, and Constellation analysis. The unique system
architecture is an affordable entry solution that can be scaled easily for future network expansions. The system is
completed by a controller software package offering 3D graphics for detailed analysis of ingress, alarm detection/
generation and trouble ticket management. A server option coupled to the system is capable of storing 30 days
of ingress monitoring data for reference.
2.0 AbouT ThIs GuIde
Every effort was made to ensure that the information contained in this installation guide is accurate. Information
is subject to change without notice and we accept no responsibility for any errors or omissions. In case of dis-
crepancy, the web version takes precedence over any printed literature.
(c) Copyright 2012 VeEX Inc. All rights reserved. VeEX, VePAL are registered trademarks of VeEX Inc and/or its
affiliates in the the USA and certain other countries. All trademarks or registered trademarks are the property of
their respective companies. No part of this document may be reproduced or transmitted electronically or other-
wise without written permission from VeEX Inc.
This device uses software either developed by VeEX Inc or licensed by VeEX Inc from third parties. The software
is confidential and proprietary of VeEX Inc. The software is protected by copyright and contains trade secrets of
VeEX Inc or VeEX’s licensors. The purchaser of this device agrees that it has received a license solely to use the
software as embedded in the device, and the purchaser is prohibited from copying, reverse engineering, decom-
piling, or disassembling the software
Audience
This guide is intended for system administrators, engineers, and operators who install and manage the CX-
180F/R. Users who perform these tasks should be familiar not only with the CX180F/R hardware and cabling,
but also with electronic circuitry, wiring practices, and safety precautions.
For more technical resources, visit VeEX Inc website at www.veexinc.com.
If you need assistance or have questions related to the use of this product, call or email our customer care de-
partment for customer support. Before contacting our customer care, have the serial number ready.
Customer Care:
Phone: +1 510 651 0500
E-mail: customercare@veexinc.com
Page 3 of 13
CX180F_R Hardware Installation Guide D07-00-018 Rev C00