OTN Tab
222
A/D ODU-j/k RX GMP Cm Lt 2
A/D ODU-j/k RX GMP Cm Gtr ltu
A/D ODU-j/k RX GMP Cm Lt ltu
A/D ODU-j/k Positive Justification
- Reports the total number of Positive
Add/Drop OPU Justification counts.
A/D ODU-j/k Negative Justification
- Reports the total number of Negative
Add/Drop OPU Justification counts.
A/D ODU-j/k Justification Seconds
- Reports the total duration of Add/Drop
OPU Justifications in seconds.
OTN Results - Event
The Results - Event function provides a detailed summary of when and how many
errors, alarms, and other specific activity that has occurred and has been recorded by
the unit since the time the test was started
The events appear in a table that lists events, the number of events logged, the start
and stop time of the event, and the duration of the event.
Select the
Descending
/
Ascending
button to toggle between the order you wish to view
the results.
Select
Pause
to temporarily halt the display of results, and press
Resume
to continue
displaying results in real-time.
OTN Results - Large LEDs
This button displays the LED Error and Alarm Indicators in a large, easy to read format
that covers the entire screen area. This is especially useful for viewing any errors or
alarms from a long distance, such as across the room from a test bay.
MPA_e_manual_D07-00-129P_RevA00
Summary of Contents for MPA
Page 2: ...MPA_e_manual_D07 00 129P_RevA00...
Page 10: ...MPA_e_manual_D07 00 129P_RevA00...
Page 82: ...MPA_e_manual_D07 00 129P_RevA00...
Page 110: ...MPA_e_manual_D07 00 129P_RevA00...
Page 134: ...MLD Tab 134 100G RS FEC Ethernet 400G RS FEC Ethernet MPA_e_manual_D07 00 129P_RevA00...
Page 255: ...Protocol Tabs 255 MPA_e_manual_D07 00 129P_RevA00...
Page 256: ...OTN Tab 256 MPA_e_manual_D07 00 129P_RevA00...
Page 748: ...MPA_e_manual_D07 00 129P_RevA00...
Page 796: ...MPA_e_manual_D07 00 129P_RevA00...