Protocol Tabs
333
The following describes the functions that may appear on the Set 3 screen, depending
on the card type and configuration.
Function
Description
Monitor Mode
Monitor Mode is currently not supported.
Signal Auto-
Recovery Method
This is used as an attempt to recover the signal in the event
the SONET's client processor signal (Packet tab, etc) is in an
alarm state such as Loss of Frame or Loss of Link.
•
By setting this to
Default
, the SONET processor will
refresh every 30 seconds or so, which gives the client
processor an opportunity to re-acquire a good framing
or link.
•
By setting this to
Alternate
, then the SONET
processor will not try to auto-recover (refresh) when
the client processor framing or link state is bad. You
may need to force an LOS event (and then clear the
LOS event) after the signal failure has been resolved,
for the client to re-acquire client framing or link state.
Signal Auto-Recovery Method is only supported on the
MPM-10G card.
SONET Receive - SOH
The Receive SOH (Section and Line Overhead) screen contains the following options:
Option
Description
MPA_e_manual_D07-00-129P_RevA00
Summary of Contents for MPA
Page 2: ...MPA_e_manual_D07 00 129P_RevA00...
Page 10: ...MPA_e_manual_D07 00 129P_RevA00...
Page 82: ...MPA_e_manual_D07 00 129P_RevA00...
Page 110: ...MPA_e_manual_D07 00 129P_RevA00...
Page 134: ...MLD Tab 134 100G RS FEC Ethernet 400G RS FEC Ethernet MPA_e_manual_D07 00 129P_RevA00...
Page 255: ...Protocol Tabs 255 MPA_e_manual_D07 00 129P_RevA00...
Page 256: ...OTN Tab 256 MPA_e_manual_D07 00 129P_RevA00...
Page 748: ...MPA_e_manual_D07 00 129P_RevA00...
Page 796: ...MPA_e_manual_D07 00 129P_RevA00...