Protocol Tabs
507
If the MPA receives an MS-RDI or HP-RDI alarm, it is reported by the MPA's LEDs and
logged to the Results screen.
The MPA can be used to simulate RDI alarms to verify if upstream NEs react
accordingly to an incoming RDI alarm.
Related Topics:
Unit reports Loss of Signal (LOS)
10G WAN testing over STM-64
For SDH mode, 10G WAN is tested over STM-46
1. Select the
SDH
tab, depending on the configured protocol mode.
2. Select
Transmit
and choose
Set >
Set 1
.
3. Verify that the
Settings Control
setting is set to
Coupled
.
4. Select
Interface
. The Select Type of Interface menu box appears.
5. Select
STM-64 (9953.28 Mbps)
.
6. Select the
Mapping
. The Select Mapping menu box appears.
7. Select
AU-4-64C Ethernet WAN
.
MPA_e_manual_D07-00-129P_RevA00