OTN Tab
254
•
The
MLD tab
allows you to configure and monitor the slice's optical power,
OTLC.n, FEC and Skew.
•
The
OTN tab
allows you to configure and monitor the slice's overhead and
traces, errors and alarms, Service Disruption and Round-Trip-Delay
measurements.
Service Disruption and RTD measurements can only be made from the OTUCn
group controlling slice (Slice #1).
For more information about OTUCn groups, see
OTUCn Examples
Depending on the configuration of an MPA unit, the OTUCn feature can support multiple
different configurations; including up to six (6) OTUC1's, three (3) OTUC2's, two (2)
OTUC3's, one (1) synchronized OTUC6, one (1) OTUC2 and one (1) OTUC4, as well
as multiple other OTUCn combinations.
Below are just a few examples of various OTUCn configurations, based on an MPA unit
with six (6)
As illustrated in the examples below, the size of the OTUCn group is based on the
number of slices (members) in the group. Hence, and OTUC2 has two slices, and
OTUC3 has three slices, etc.
Each OTUCn group also has a unique group identification number (#), based on the
Slot # of the group's controlling slice (Slice #1's Slot #).
MPA_e_manual_D07-00-129P_RevA00
Summary of Contents for MPA
Page 2: ...MPA_e_manual_D07 00 129P_RevA00...
Page 10: ...MPA_e_manual_D07 00 129P_RevA00...
Page 82: ...MPA_e_manual_D07 00 129P_RevA00...
Page 110: ...MPA_e_manual_D07 00 129P_RevA00...
Page 134: ...MLD Tab 134 100G RS FEC Ethernet 400G RS FEC Ethernet MPA_e_manual_D07 00 129P_RevA00...
Page 255: ...Protocol Tabs 255 MPA_e_manual_D07 00 129P_RevA00...
Page 256: ...OTN Tab 256 MPA_e_manual_D07 00 129P_RevA00...
Page 748: ...MPA_e_manual_D07 00 129P_RevA00...
Page 796: ...MPA_e_manual_D07 00 129P_RevA00...