Packet Tab
548
Automated Test
Sequence
The following parameters allow the user to configure and test
each of the RFC tests, so that one will run after the previous
test completes.
•
Thruput/Latency checkbox and status field
•
Frame Loss checkbox and status field
•
B2B Burst checkbox and status field
•
Start/Stop Button
•
Test Status field
The following list of tasks demonstrate how to configure and test each of the RFC-
2544 benchmark tests.
•
To
Configure the RFC-2544 test
•
To run an
RFC-2544 Thru Put
•
To run an
RFC-2544 Frame Loss
•
To run an
RFC-2544 B2B Burst
RFC Tests - Through Put Test (Thru Put)
This is an RFC 2544 benchmark test that calculates your network's throughput rate. The
fastest throughput speed is indicated by the rate at which the transmission and
reception of the Ethernet test stream is accomplished without packet loss.
The following options appear on the Thru Put screen:
Option
Description
Stream ID
Displays the ID number of the stream that will be used for the
RFC test.
is configured from the RFC Tests - Conf
screen.
Trial Duration
Displays how long the test will run for each packet size. This
MPA_e_manual_D07-00-129P_RevA00
Summary of Contents for MPA
Page 2: ...MPA_e_manual_D07 00 129P_RevA00...
Page 10: ...MPA_e_manual_D07 00 129P_RevA00...
Page 82: ...MPA_e_manual_D07 00 129P_RevA00...
Page 110: ...MPA_e_manual_D07 00 129P_RevA00...
Page 134: ...MLD Tab 134 100G RS FEC Ethernet 400G RS FEC Ethernet MPA_e_manual_D07 00 129P_RevA00...
Page 255: ...Protocol Tabs 255 MPA_e_manual_D07 00 129P_RevA00...
Page 256: ...OTN Tab 256 MPA_e_manual_D07 00 129P_RevA00...
Page 748: ...MPA_e_manual_D07 00 129P_RevA00...
Page 796: ...MPA_e_manual_D07 00 129P_RevA00...