Left/Right button
: To move the pulse mask to left or right direction, press the left or right button first and re-run the test.
13.2 DS3 Tools > FEAC
DS3 FEAC responses (Far End Alarm and Control Channel Responses):
Enabling this option allows loop-back to be configured from any “far-end” equipment connected on the other end of the line.
These can be used to send and receive loop up codes and information from the far end T3 device. You can enable and disable
through a drop down menu in this field.
Loop UP Activate: 00010010 11111111 sent >10 repetitions
Loop Down Deactivate: 00100100 11111111 sent >10 repetitions
FEAC alarms are sent from the remote end device towards the local device by means of the C bit in the Sub-frame. When a
failure is declared on the remote end unit this is how it notifies the near end unit. Some FEAC Codes are shown below
Alarm TYPE
DS3 Equip. Failure(Service Affecting)
TX150 e-Manual D07-00-023 Rev A02