8.1.4 Results > Signal
The Signal tab brings up the Frequency and Level Result screen.
Frequency:
The received signal frequency and offset is measured and displayed. For DS1 signals, the measurement is
performed on both balanced 100ohm and unbalanced 75ohm interfaces.
- Current: Indicates the frequency of the input signal
- Offset: Indicates the difference between the standard rate and the rate of the input signal
- Min (ppm): Indicates the difference between the standard rate and the minimum deviation detected in the input signal
- Max (ppm): Indicates the difference between the standard rate and the maximum deviation detected in the input signal
A Min (ppm) and Max (ppm) function can be used to ensure that the received signal is within a certain clock tolerance and that
the network element is transmitting correctly. The frequency limits for the various signal types according to ITU-T
recommendations are presented in the table below.
TX150 e-Manual D07-00-023 Rev A02