background image

 

 

Vega SH-2 / User Manual 

 

 

24 

Revision 06 – 06 July 2020  

 

LTE-modem signal quality is from 0 to 31 when there is a connection,  but 99 value 

means that there is no connection. See details in the table below. 

Value displayed in application 

Signal quality, dBm 

-113 and lower 

-111  

2…30 

-109…-53  

31 

-51 and more 

99 

No connection 

100 

-116 and lower 

101 

-115 

102…190 

-114…-26 

191 

-25 and more 

199 

No connection 

“Force compose packet” button – 

by pressing the button the device collects readings 

from all interfaces, forms the packet and put it in the black box. 

One Wire

  –  the settings of connection any  external  temperature sensors and its 

readings.  For adding a temperature sensor, you should  switch the auto adding mode on. 
Every sensor will get a number in order it was connecting. After switching the auto adding 
mode on, the device search for  some  new sensors on the bus. If  there is a sensor then the 
device adds it in memory and switch the auto adding mode off. To add the next sensor, you 
should switch the auto adding mode on again. All sensor removed from the device memory 
by pressing the button “Delete all sensors”. 

Interface settings

  –  allows setting up the type of every input –  it may be pulse or 

security mode  and choose the input mode 1-Wire/ModBus. If you choose the 1-Wire then 
ModBus settings does not available, if you choose the ModBus then 1-Wire and temperature 
sensors settings does not available.  

Guard  settings

  –  allows  setting  up the work of security inputs, namely,  what kind of 

security circuit state is reason to send an alarm message: short, open, or both. 

Connection settings

 – a group of parameters that allows you to configure the collection 

and transmission periods, and the time zone and choose the technology of data transmitting 
and LTE-modem mode.  

Time zone specified for the setting of the internal clock of the device. 

Readings collected by the internal device clock at the 0:00 AM if the collection period 

equal to 24 hours, at the 0:00 AM and 12:00 AM if the period equal to 12 hours and so on. All 
reading stored in the device memory until the next communication session.  

Transmission period may be equal to 5, 15, 30 minutes, 1, 6, 12 or 24 hours. At the next 

communication session, the device starts sending accumulated packets with readings, from 
the earliest to the latest.  The specific data transfer time cannot be set, it is determined 
randomly for each device within the selected data transmission period from the moment of 

Summary of Contents for SH-02

Page 1: ...www vega absolute ru LORAWAN NB IOT MODEM VEGA SH 02 User manual...

Page 2: ...Product name End devices Vega SH 02 Revision History Revision Date Name Comments 01 25 03 2019 KEV Document creation date 02 05 04 2019 KEV Case dimensions are changed 03 15 07 2019 KEV Minor changes...

Page 3: ...n 12 Connecting via USB 13 4 VEGA LORAWAN CONFIGURATOR 14 Interface of the application 14 Connection to the device 15 Device info tab 17 LoRaWAN settings tab 19 Vega SH 02 tab 23 5 COMMUNICATION PROTO...

Page 4: ...ide the stable radio between the gateway and the end device it is recommend avoiding the device installation in the places which are barriers for the radio signal getting through like a reinforced flo...

Page 5: ...unication session with LoRaWAN network Memory can hold up to 100 packets The modem has two digital inputs which may be configured as pulse or security Besides the device has two analog inputs 1 Wire a...

Page 6: ...e battery and communication period 24 hours LTE NB IoT antenna type external LoRaWAN LoRaWAN class A Quantity of LoRaWAN channels 16 Frequency plan RU868 EU868 IN865 AS923 AU915 KR920 US915 KZ865 cust...

Page 7: ...1 2 COUNT2 Digital input 2 3 GND Ground 4 GND Ground 5 ADC1 Analog input 1 0 21 6 ADC2 Analog input 2 0 21 7 RS485_A RS 485 Interface A 8 RS485_B RS 485 Interface B 9 ONE_WIRE 1 Wire Interface 10 GND...

Page 8: ...oose the event for security input triggering via the Vega LoRaWAN Configurator application Analog inputs ADC1 and ADC2 may be used for measuring an external voltage from 0 to 21 V RS 485 modbus and 10...

Page 9: ...when the operating modes are changed Also there is a green LED which used only for configuring during manufacture LED signal Meaning Flash every 5 seconds Device not sleeping USB connection LoRaWAN t...

Page 10: ...IoT technology Two short flashings every 2 seconds Linking to the NB IoT network Three short flashings every 2 seconds The device connected to the network and transmits the data on the server Short fl...

Page 11: ...e part 4 LORAWAN TECHNOLOGY OPERATION The modem supports two activation methods in the LoRaWAN network ABP and OTAA Select one of the methods using Vega LoRaWAN Configurator application See part 4 1 A...

Page 12: ...see part 4 and set SIM card in the slot on the board When some event occurs schedule time alarm etc the modem begins registration in the network After registration and data transmitting or if the dat...

Page 13: ...the first time you must install the driver for the COM port stsw stm32102 which can be download from iotvega com After running the executable file VCP_V1 4 0_Setup exe the installer window will appea...

Page 14: ...T module operation The configurator has two modes of operation Simple and Expert In the Simple mode only basic settings are available In the Expert mode the basic settings advanced settings and the ab...

Page 15: ...s in the upper right corner CONNECTION TO THE DEVICE For the connection to the device perform the following steps 1 Connect the USB cable to the device 2 Start the Vega LoRaWAN Configurator applicatio...

Page 16: ...H 2 User Manual 16 Revision 06 06 July 2020 After making the necessary changes to the settings you should click the Apply settings button and only then disconnect from the device with the Disconnect b...

Page 17: ...Air Activation is displayed Key management not displayed in the Simple mode allows you to change the factory keys to register the device on the network and reset the keys back to the factory settings...

Page 18: ...dy connected to the network reconnection procedure will occur Link check not displayed in the Simple mode when pressed the device sends a special signal to the LoRaWAN network in response to which the...

Page 19: ...25 kHz 3 868 5 MultiSF 125 kHz RX2 869 525 SF12 125 kHz RU 868 1 868 9 MultiSF 125 kHz 2 869 1 MultiSF 125 kHz RX2 869 1 SF12 125 kHz Custom Set up in application In the device frequency plan only tho...

Page 20: ...onsidered empty Activation type displays ABP or OTAA device activation method Confirmed uplinks when you choose confirmed the device will retry sending the packet until it receives the server confirma...

Page 21: ...will open the first receiving window to receive confirmation for the join request from the LoRaWAN network while OTAA mode active The second window always opens after 1 second after the first Uplink n...

Page 22: ...alue when sending packets to the LoRaWAN network This option can be changed by the network server if the ADR algorithm is enabled TX datarate not displayed in the Simple mode the device transmission d...

Page 23: ...02 TAB The Vega SH 02 tab contains the settings of the connected device Current state displays the current parameters of the device the number of counted pulses at the inputs LTE modem state and signa...

Page 24: ...ings allows setting up the type of every input it may be pulse or security mode and choose the input mode 1 Wire ModBus If you choose the 1 Wire then ModBus settings does not available if you choose t...

Page 25: ...nication session until the next one according to the schedule In this case the device continues to collect data according to the data collection period and store it in memory Non transmitted packets r...

Page 26: ...nt32 1 byte Temperature int8 20 bytes Readings of the ten external temperature sensors 0 1 Or readings of the ten ModBus registers int16 uint16 4 bytes Pulse number on the input 1 uint32 4 bytes Pulse...

Page 27: ...Vega SH 2 User Manual 27 Revision 06 06 July 2020 8 bytes The value in seconds for which you need to adjust the time Can be positive or negative int64...

Page 28: ...fy a topic name where the data published and a client name the name which the device use for publishing All those settings specified in Vega LoRaWAN Configurator in part MQTT over LTE settings For wat...

Page 29: ...EARFCN the number of radio frequency channel absolute PCID physical network address RSRP input signal power RSRQ input signal quality RSSI indicator of the input signal power SNR signal to noise ratio...

Page 30: ...ATION REQUIREMENTS Vega SH 02 modem shall be stored in the original packaging in heated room at temperatures 5 to 40 and relative humidity less than 85 The modem shall be transported in covered freigh...

Page 31: ...6 06 July 2020 7 CONTENT OF THE PACKAGE The modem is delivered complete with Vega SH 02 modem 1 pc Antenna 2 pcs 6400 mAh battery 1 or 2 pcs 3 Factory certificate 1 pc 3 The number of delivered batter...

Page 32: ...and operation specified in this user manual Warranty does not apply to power supplies of devices the device with mechanical electrical and or other damages and defects caused by violation of the trans...

Page 33: ...Vega SH 2 User Manual 33 Revision 06 06 July 2020 vega absolute ru User Manual Vega Absolute OOO 2019 2020...

Reviews: