background image

Vega Light Control Systems 

● Holland, Michigan 49424

 

2.3.  STEP 3: Install retrofit kit in fixture 

 

 
 
 

 

 
 
 
 
 
 
 
 
 
 

 

Power Supply Above or Mid Mount 

 

Power Supply Down below Mounting Plate 

 

Notes: 

  For Type 3, ensure LED head is rotated with 

“Street Side” of light engine facing the street (see 1.4.6) 

  Re-use screws previously holding HID ballast to fixture to attach Retrofit Kit when possible. Additional hardware 

maybe required. 

  For Post Top fixtures, LED Light should be installed to maintain cooling clearance above heatsink and at arc 

tube height of replaced HID.

 

(see 1.4.5) 

  Restore the original light fixture sealing for water and insect control. Rain water must not enter the wiring 

compartment. 

 

CENTER POLE MOUNTING 

 

Summary of Contents for D4-C

Page 1: ...SDICTION RISQUE D INCENDIE OU DE CHOC LECTRIQUE L INSTALLATION DE CE N CESSAIRE DE MODERNISATION EXIGE UNE PERSONNE FAMILI RE AVEC LA CONSTRUCTION ET LE FONCTIONNEMENT DU SYST ME LECTRIQUE DU LUMINAIR...

Page 2: ...FIXTURE AMBIENT OPERATING TEMPERATURE FOR LED RETROFIT MODULE 104 F 40 C MAXIMUM AMBIENT OPERATING TEMPERATURE CANNOT EXCEED 140 F 60 C INSTALLATION REQUIREMENTS MAY VARY DEPENDING ON THE LUMINAIRE R...

Page 3: ...plication Specific configuration for mounting in Granville Classic 7 and 4 fitters with 19 glass globes One piece assembly Granville Premier Kit Style Watts CCT Type Mounting Dimming Mounting Code Det...

Page 4: ...mm LED Light Engine Height Adjustable From 15 Down To 9 75 D4 F Model Fully Enclosed 60W Max Adapter Plate D4 S Down Light Model with Side Brackets D4 M Model Mid Mount Enclosed 80W Max 4 73 or 5 91...

Page 5: ...LexaLite Lindy 408 globe performs best at LED height set 8 from the base of the globe Crown 88266 CL has an optimum output when set 13 from the base of the globe 5 Measure the maximum temperature achi...

Page 6: ...efore servicing WARNING Risk of burn Allow unit to cool fully before servicing POST TOP Note Failure to remove original components including ballast will void product warranty Original optical compone...

Page 7: ...ght tighten set screw enough to hold tube then tighten another turn with hex key see 1 4 2 4 Side brackets can be adjusted bent trimmed or special ordered to span or offset LED mounting height Allow a...

Page 8: ...acing the street see 1 4 6 Re use screws previously holding HID ballast to fixture to attach Retrofit Kit when possible Additional hardware maybe required For Post Top fixtures LED Light should be ins...

Page 9: ...Black or Blue using pre installed Lever Nuts If photocell controlled or remote controlled connect Retrofit Kit to output of the control 2 5 STEP 5 Secure fixture components Secure fixture components a...

Page 10: ...rranty period contact VEGA sales representative for RMA 3 If out of warranty period contact VEGA sales representative for information to replace surge protector LEDs are dim or not lit 1 DC Cable is u...