16
DSGH Installation and Operation Guide
Introduction
GEN2000
®
Electronics
Housing
4-wire
hookup with
DC
1.02 – 0.643 mm (no. 18 or 20 AWG) 4-conductor
shielded
Certification
to CSA and
UL
standards
• Designed to meet National Electric Code (U.S.
and Canada)
• Class l, Groups A, B, C and D, Div 1 and 2
• Class ll, Groups E, F and G, Div 1 and 2
ATEX
Certification
II 2 G Ex d IIC T6 Gb
II 2 G Ex d IIB+H2 T6 Gb
II 2 D Ex tb IP66 T60°C Db
Enclosure
rating
NEMA 4X IP-66
Ambient
temperature
-20 °C ...+
6
0 °C (-4 °F ...+1
40
°F) option for lower
temperatures available
Humidity
0 – 95%, non-condensing
Vibration
Tested to IEC 68-2-6, IEC 68-2-27, and IEC 68-2-
36
Material
Cast aluminum ASTM A 357
Paint
Polyester Powder Coating
Table 1.1
DSGH specifications (continued)