The "System" tab displays information about the device, about modem, and SIM.  

 

Device info - the configurator reads information about the device model, its firmware 

and automatically corrects the device's time when connected to it. In that block you can find 
out the number of records in the black box and the number of packets sent by the device. 

Modem info – in that block information about LTE-modem is displayed. 

SIM – identifiers of the SIM card (SIM chip). 

Summary of Contents for NB-11

Page 1: ...www vega absolute ru NB IoT Pulse Counter VEGA NB 11 User manual ...

Page 2: ...ument number V02 NB11 01 Revision and date 03 08 October 2020 This document applies to the following products Product name Type number Vega NB Vega NB 11 Revision History Revision Date Name Comments 01 17 06 2019 KEV The first release 02 14 07 2020 KEV Minor changes 03 08 10 2020 KEV We recalculate the number of transmitted packets in warranty conditions ...

Page 3: ... Marking 6 2 SPECIFICATION 7 3 OPERATION 8 Contacts 8 Hall sensor 9 Buttons 10 Indication 11 Initial Startup 12 Connecting via USB 12 4 VEGA NB IoT CONFIGURATOR 14 Interface of the application 14 Connection to the device 15 System tab 16 Settings tab 17 Vega NB 11 tab 18 5 COMMUNICATION PROTOCOL 19 6 STORAGE AND TRANSPORTATION REQUIREMENTS 21 7 CONTENT OF THE PACKAGE 22 8 WARRANTY 23 ...

Page 4: ... and functions of the counter This manual is targeted at specialists familiar with installation work fundamentals of electronic and electrical equipment The counter shall be installed and adjusted by qualified specialists in order to ensure proper operation of the device Vega Absolute OOO reserves the right to make changes to the manual related to the improvement of equipment and software as well ...

Page 5: ...g from the meter with a configurable period 5 15 30 minutes 1 6 12 or 24 hours The readings stored in the device memory and transmitting during the next communication session with the NB IoT network The adjustable data transfer period can be equal to 5 15 30 minutes 1 6 12 and 24 hours Data transferring in random point in time during set period At the next communication session the device starts s...

Page 6: ...Queue of sending when delivery is not possible o Time referencing of readings by internal clock o Communication in case of security inputs or Hall sensor actuation o Temperature measurement o Charge measuring of the built in battery MARKING Device marked with sticker that contain the next information o Device model o IMEI o Month and year of manufacture o QR code containing IMEI for automatized co...

Page 7: ...lt in temperature sensor yes Hall sensor yes Quantity of black box records up to 100 000 Cellular communications Supported Cellular Standards LTE Cat NB1 Data transfer protocol MQTT Guaranteed number of transmitted packets if the data transferring once a day 3600 LTE NB IoT antenna type external Power Built in battery 6400 mAh Case Housing dimensions 95 х 95 х 50 mm Ingress protection rating IP67 ...

Page 8: ...hanical pushbutton open collector output Equipment with NAMUR pulse output is not supported Polarity effects only open collector circuits There are two security inputs on the board The device monitors status changes on the security inputs and when the security input triggers the device is activated and sends an alarm message to the network Circuit design of the pulse inputs ...

Page 9: ... October 2020 HALL SENSOR The device has Hall sensor which located on the board edge on the bottom side When the magnet is brought up the sensor triggered and the device can form the alarm message which immediately transmitted to the server ...

Page 10: ...ce reloading INIT Pressing for 1 second Registration at the network Pressing for 2 seconds Data transmitting Pressing for 3 seconds LTE modem switching off When you hold down the button the red LED starts flashing once a second which will help you to find out the duration of pressing Pressing for 1 second corresponds to one flash of the LED pressing for 2 seconds corresponds to two and so on INIT ...

Page 11: ...y three seconds Device search the network Short flash every second Device successfully registered and it is in the network Two short flashes every one second Device transmits data to the network No light LTE modem switched off Device Short flash every second Battery charge is lower than 5 Short flash every five seconds Device in the Operation mode No light Device in the Sleep mode or switched off ...

Page 12: ...the schedule If you need to test the data transmitting then press and hold the INIT button for the 2 seconds CONNECTING VIA USB The pulse counter can be adjusted with the Vega NB IoT Configurator application through the USB connection See part 4 Before connecting the device to the computer for the first time you must install the driver for the COM port stsw stm32102 which can be downloaded from io...

Page 13: ...window you need to click Next then Install and then the installation will begin When the installation is completed successfully the following screen appears After pressing Finish the driver is ready for operation it is possible to connect the pulse counter via USB ...

Page 14: ...ia USB INTERFACE OF THE APPLICATION The Vega NB IoT Configurator application does not require the special installation When the executable file is launched the window for working with the application appears The menu on the left allows you to select the device model connect to the device or disconnect from it and update firmware The application window contains three tabs System Settings and device...

Page 15: ...the device selection menu becomes inactive To read the settings from the device you need to click the Get settings button until this point the application will display the default settings or from the last connected device After making the necessary changes to the settings you should click the Apply settings button and only then disconnect from the device with the Disconnect button Also the applic...

Page 16: ... configurator reads information about the device model its firmware and automatically corrects the device s time when connected to it In that block you can find out the number of records in the black box and the number of packets sent by the device Modem info in that block information about LTE modem is displayed SIM identifiers of the SIM card SIM chip ...

Page 17: ...twork in the specific covering conditions Cellular operator can give you APN or set it by default if the field is empty Time zone set up for the data collection period which is equal to the device time UTC plus time zone Transmission period is always use UTC time regardless of the time zone setting Readings collected at 00 00 if the collection period is 24 hours at 00 00 and at 12 00 if the period...

Page 18: ...umber of retries is 5 Guard inputs settings allows to set up mode of security inputs triggering when security circuit is short open or in a both cases MQTT settings settings of connection with MQTT broker VEGA NB 11 TAB The Vega NB 11 tab contains detail information about the connected device its sensors and inputs Network displays the current parameters of the connection and allows to control it ...

Page 19: ...blishing All those settings specified in Vega NB IoT Configurator in part MQTT settings For watching the data sending by the device you should to deploy MQTT broker on a PC and subscribe some application on MQTT broker Vega NB 11 sends the message on the server as a text of JSON format See example below Message dev NB 11 v0 5 IMEI 867723030711633 IMSI 250990283462252 ICCID 8970199170730496963 num ...

Page 20: ...ason for packet forming UTC the date and the time of message collecting in UTC format by Greenwich bat battery charge temp processor temperature pulse1 pulse number on the input 1 pulse2 pulse number on the input 2 pulse3 pulse number on the input 3 pulse4 pulse number on the input 4 Possible values for Reason field Reason for packet forming time packet formed by the time data collection period se...

Page 21: ...N REQUIREMENTS Vega NB 11 pulse counter shall be stored in the original packaging in heated room at temperatures 5 С to 40 С and relative humidity less than 85 The counter shall be transported in covered freight compartments of all types at any distance at temperatures 40 C to 85 C ...

Page 22: ...B 11 User Manual 22 Revision 03 08 October 2020 7 CONTENT OF THE PACKAGE The pulse counter is delivered complete with Vega NB 11 pulse counter 1 pc Antenna 1 pc Battery 6400 mAh 1 pc Factory certificate 1 pc ...

Page 23: ...specified in this user manual Warranty does not apply to the batteries of devices which sent more than 3600 packets the device with mechanical electrical and or other damages and defects caused by violation of the transportation storage and operation requirements the device with traces of repair performed not by the manufacturer s service center the device with traces of oxidation or other signs o...

Page 24: ...Vega NB 11 User Manual 24 Revision 03 08 October 2020 vega absolute ru User Manual Vega Absolute OOO 2019 2020 ...