60
63138-US-200110
7.4 Diagnostics
The source holder does not have any diagnostics that alert users to potential
problems. However, emergency guidelines as outlined in the
Radiation Safety
Manual
provide steps you can take for the following emergency situations:
•
Stuck Shutter or Inoperable Cable
•
Loss or Theft
•
Entering a Tank or Vessel
•
Fall, Collision, or Fire
7.5 Troubleshooting
The source holder is extremely reliable, but errors can occur during operation.
Some of those potential problems are caused by the following:
General cleanliness
Annually
Make certain there is no
buildup of dirt or process
material on the source holder.
Corrosion or rusting
Annually
Check the housing, winches,
and the shutter/lock pin.
Painting
As needed
Clean and paint as necessary.
Do not paint labels.
Item
Action to Take
Abandoned or discarded source In the United States, contact the U.S. NRC or
an agreement state.
Damaged or failed source
Retract the capsules into the shielded
position, if possible and contact VEGA
Americas Nuclear Services.
Missing or broken lock
Do not remove the source from the crate or
mount the source. If the source is already
mounted, contact VEGA Americas Nuclear
Services.
Description
Frequency
Procedure
Summary of Contents for SHLD 2
Page 1: ...Operating Instructions SHLD 2 Source Holder Document ID 63138 Radiometric...
Page 2: ......
Page 8: ...6 63138 US 200110 NOTES...
Page 12: ...10 63138 US 200110 NOTES...
Page 26: ...24 63138 US 200110 NOTES...
Page 42: ...40 63138 US 200110 NOTES...
Page 56: ...54 63138 US 200110 NOTES...
Page 68: ...66 63138 US 200110 NOTES...
Page 78: ...76 63138 US 200110 9 2 Dimensions Figure 9 7 Source Holder SHLD 2 Standard Version...
Page 79: ...63138 US 200110 77 Figure 9 8 SHLD 2 Beam Angles Figure 9 9 SHLD 2 Height for Source Exchange...
Page 80: ...78 63138 US 200110 Figure 9 10 Source Holder SHLD 2 with Limit Switch...
Page 81: ...63138 US 200110 79 Figure 9 11 Source Holder SHLD 2 with Interlock Safety Switch...
Page 82: ...80 63138 US 200110 Figure 9 12 Source Holder SHLD 2 with Air Actuator...
Page 83: ...63138 US 200110 81 Figure 9 13 Source Holder SHLD 2 with Air Actuator and Limit Switch...
Page 84: ...82 63138 US 200110 Figure 9 14 Source Holder SHLD 2 Explosion Proof with Limit Switch...
Page 86: ...84 63138 US 200110 NOTES...
Page 87: ......