Vega SI-12 / User Manual
22
Revision 12 – 03 July 2020
“VEGA SI-12” TAB
The “Vega SI-12” tab contains the settings of the connected device.
Current state
– displays the current parameters of the device - the number of counted
pulses at the inputs, the temperature, the battery level and the current LoRaWAN class.
To reset the collected readings from device memory, it is necessary to put the device
in the "Storage" mode by pressing the button on the board for a long time (more than 5
seconds) (see section "Initial startup").
Input settings
– allow you to change the operation of the pulse inputs from the
counting of pulses to the security mode and back. When transferring the input to the security
mode, the device will send an alarm packet to the network (See part 5, packet 2) whenever
this input is closed. The maximum possible frequency of sending alarm packets is one per 1
second.
Guard settings
– allows setting up the work of security inputs, namely, what kind of
security input state changing is reason to send an alarm message: short, open, or both.