Table of ID of SI-12 parameters and these possible values
ID of
parameter
Description
Data
length
Possible values
4
Confirmed uplinks
1 byte
1 – confirmed
2 – unconfirmed
8
Uplinks number of transmissions
1 byte
from 1 to 15
12
Input 1 mode
1 byte
1 – pulse
2 – guard
13
Input 2 mode
1 byte
1 – pulse
2 – guard
14
Input 3 mode
1 byte
1 – pulse
2 – guard
15
Input 4 mode
1 byte
1 – pulse
2 – guard
16
Communication period
1 byte
1 – 1 hour
2 – 6 hours
3 – 12 hours
4 – 24 hours
5 – 5 minutes
6 – 15 minutes
7 – 30 minutes
49
Data collection period
1 byte
1 – 1 hour
2 – 6 hours
3 – 12 hours
4 – 24 hours
5 – 5 minutes
6 – 15 minutes
7 – 30 minutes
55
Time zone, in minutes
2 bytes
from -720 to 840