6
T
echnical data
G
eneral data
316
L
corresponds to
1
.
4404
or
1
.
4435
C
ommon data
M
aterials
,
non
-
wetted parts
-
E
lectronics housing
P
lastic
PBT
(
polyester
),
A
lu die
-
casting powder
-
coated
,
316
L
-
S
eal
NBR
(
stainless steel housing
),
silicone
(
A
lu
/
plastic housing
)
-
I
nspection window in housing cover for
PLICSCOM
P
olycarbonate
-
G
round terminal
316
T
i
/
316
L
VEGABAR
51
M
aterials
,
wetted parts
-
P
rocess
fi
tting
316
L
-
P
rocess diaphragm
316
L
,
H
astelloy
C
276
,
H
astelloy
C
2
,
T
antalum
,
T
itanium
,
PTFE
on
316
T
i
,
gold
-
coating on
316
L
W
eight approx
.
0
.
8
…
8
kg
(
1
.
8
…
17
.
6
lbs
),
depending on the housing material and
process
fi
tting
VEGABAR
52
M
aterials
,
wetted parts
-
P
rocess
fi
tting
316
L
,
H
astelloy
C
276
,
PVDF
-
D
iaphragm
sapphire
-
ceramic
®
(
99
.
9
%
oxide ceramic
A
l
2
O
3
)
-
J
oining material diaphragm
/
B
asic element measuring cell
G
lass solder
-
M
easuring cell seal
FKM
(
A
+
P
70
.
16
-
06
),
FFKM
(
K
alrez
6375
),
EPDM
(
A
+
P
75
.
5
KW
/
75
F
),
silicone
,
FFKM
(
C
hemraz
535
)
-
S
eal
,
process
fi
tting
K
lingersil
C
-
4400
,
T
esnit
W
eight approx
.
0
.
8
…
2
.
3
kg
(
1
.
8
…
5
.
1
lbs
),
depending on housing material
VEGABAR
53
M
aterials
,
wetted parts
-
P
rocess
fi
tting
316
T
i
-
D
iaphragm standard
316
T
i
-
D
iaphragm from measuring range
25
bar
,
with not
fl
ush version
E
lgiloy
2
.
4711
-
S
eal ring
,
O
-
ring
FKM
(
VP
2
/
A
),
EPDM
(
A
+
P
75
.
5
/
KW
75
F
),
NBR
(
COG
),
FFKM
(
C
hem
-
raz
535
)
I
nternal transmission liquid
S
ynthetic oil
,
H
alocarbon oil
3
)
4
)
W
eight approx
.
0
.
8
…
2
.
3
kg
(
1
.
8
…
5
.
1
lbs
),
depending on the housing material and
process
fi
tting
VEGABAR
54
M
aterials
,
wetted parts
-
P
rocess
fi
tting
316
L
,
PVDF
,
PVDF
plated
,
H
astelloy
C
4
plated
-
D
iaphragm
sapphire
-
ceramic
®
(
99
.
9
%
oxide ceramic
A
l
2
O
3
)
-
M
easuring cell seal
FKM
(
VP
2
/
A
),
FFKM
(
K
alrez
6375
),
EPDM
(
A
+
P
75
.
5
/
KW
75
F
),
FFKM
(
C
hemraz
535
),
FFKM
(
FDA
/
3
A
)
W
eight approx
.
0
.
8
…
8
kg
(
1
.
8
…
17
.
6
lbs
),
depending on the housing material and
process
fi
tting
O
utput variable
4
…
20
m
A
/
HART
O
utput signal
4
…
20
m
A
/
HART
S
ignal resolution
1
.
6
µ
A
F
ailure signal
current output unchanged
20
.
5
m
A
,
22
m
A
,
>
22
m
A
,
<
3
.
6
m
A
(
adjustable
depending on the instrument type
)
M
ax
.
output current
22
m
A
L
oad
see load diagram under
P
ower supply
D
amping
0
…
999
s
,
adjustable
S
tep response or adjustment time
150
ms
(
ti
:
0
s
;
0
…
100
%
)
F
ul
fi
lled
NAMUR
recommendations
NE
43
T
echnical data
14
P
rocess pressure
/
H
ydrostatic
–
P
ressure measurement
3
)
S
ynthetic oil for measuring ranges up to
16
bar
,
FDA
listed for the food processing industry
.
F
or measuring ranges up to
25
bar dry measuring
cell
.
4
)
H
alocarbon oil generally with oxygen applications
,
not with vacuum and absolute pressure measuring range
<
1
bar
abs
.
29234
-
EN
-
081013