9 Supplement
VEGACAP 35 • Relay (DPDT)
33759-EN-230510
Ʋ
Max.
253 V AC, 253 V DC
With circuits > 150 V AC/DC, the relay contacts must be
in the same circuit.
Switching current
Ʋ
Min.
10 µA
Ʋ
Max.
3 A AC, 1 A DC
Breaking capacity
Ʋ
Min.
50 mW
Ʋ
Max.
750 VA AC, 54 W DC
If inductive loads or stronger currents are switched
through, the gold plating on the relay contact surface will
be permanently damaged. The contact is then no longer
suitable for switching low-level signal circuits.
Potential separation
> 500 V DC
Contact material (relay contacts)
AgNi (Au plated) or AgSnO (Au plated)
Modes (switchable)
A (overfill protection)/B (dry run protection)
Switching delay
Ʋ
When immersed
0.7 s
Ʋ
When laid bare
0.7 s
Ʋ
In the event of a fault
1 s
Ambient conditions
Ambient temperature on the housing
-40 … +80 °C (-40 … +176 °F)
Storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
Process pressure
-1 … 16 bar/-100 … 1600 kPa (-14.5 … 232 psig)
See following diagram
Process temperature
See following diagram