31
9 Supplement
VEGACAP 67 • Two-wire
31317-EN-200929
Process conditions
Process pressure
-1 … 16 bar/-100 … 1600 kPa (-14.5 … 232 psig)
Process temperature (thread or flange temperature)
Ʋ
Standard
-50 … +300 °C (-58 … +572 °F)
Ʋ
with external housing
-50 … +400 °C (-58 … +752 °F)
2
1
3
200°C
(292°F)
300 °C
(572°F)
100°C
(212°F)
400°C
(752°F)
0°C
(32°F)
-50°C
(-58°F)
16 bar
(232psi)
Fig. 20: Process temperature - Process pressure
1 Process temperature
2 Process pressure
3 Temperature range with external housing
Dielectric constant
≥ 1.5
Electromechanical data - version IP66/IP67 and IP66/IP68 (0.2 bar)
Options of the cable entry
Ʋ
Cable entry
M20 x 1.5; ½ NPT
Ʋ
Cable gland
M20 x 1.5; ½ NPT
Ʋ
Blind plug
M20 x 1.5; ½ NPT
Ʋ
Closing cap
½ NPT
Wire cross-section (spring-loaded terminals)
Ʋ
Massive wire, stranded wire
0.2 … 2.5 mm² (AWG 24 … 14)
Ʋ
Stranded wire with end sleeve
0.2 … 1.5 mm² (AWG 24 … 16)
Electromechanical data - version IP66/IP68 (1 bar)
Options of the cable entry
Ʋ
Cable entry
M20 x 1.5; ½ NPT
Ʋ
Cable gland
M20 x 1.5; ½ NPT
Ʋ
Blind plug
M20 x 1.5; ½ NPT
Ʋ
Closing cap
½ NPT
Connection cable
Ʋ
Wire cross-section
> 0.5 mm² (AWG 20)
Ʋ
Wire resistance
< 0.036 Ω/m (0.011 Ω/ft)
Ʋ
Tensile strength
< 1200 N (270 lbf)
Ʋ
Standard length
5 m (16.4 ft)
Ʋ
Max. length
1000 m (3280 ft)
Ʋ
Min. bending radius
25 mm (0.984 in) with 25 °C (77 °F)
Ʋ
Diameter approx.
8 mm (0.315 in)
Ʋ
Colour - standard PE
Black
Ʋ
Colour - standard PUR
Blue