4 Mounting
VEGAMIP R61 • Receiving unit
35786-EN-171120
2
1
Fig. 11: Front flush mounting
1 Unfavourable mounting - bulk solid can settle in front of the sensor
2 Correct front-flush mounting
If a front-flush mounting is not possible, you can fill long sockets with
a plastic or ceramic cylinder to avoid build up of bulk solids and dust
deposits. Select the material according to the diameter of the socket
and adapt the length as far as possible to the shape of the vessel wall.
Secure the filling material against falling out or turning. If using a fixing
screw is technically not possible, you can secure the material in the