39
9 Supplement
VEGAMIP R61 • Receiving unit
35786-EN-171120
Instrument weight (depending on pro-
cess fitting)
0.8 … 4 kg (0.18 … 8.82 lbs)
Process fittings
Ʋ
Pipe thread, cylindrical (ISO 228 T1) G1½
Ʋ
Pipe thread, conically
1½ NPT
Ʋ
Flanges
DIN from DN 50, ASME from 2"
Ʋ
Mounting adapter
G2 or 2 NPT
Frequency range
K band, 24.085 GHz (ISM band)
Measuring range
0.1 … 100 m (0.33 … 328 ft)
Beam angle
1)
Ʋ
Threaded version, internal horn an-
tenna with PTFE cover
20°
Ʋ
Plastic encapsulated antenna with PP
cover
10°
Ʋ
Horn antenna (316L), ø 40 mm
(1.575 in)
22°
Ʋ
Horn antenna (316L), ø 48 mm
(1.89 in)
18°
Ʋ
Encapsulated antenna with PTFE
cover, Flange DN 50, ASME 2"
18°
Ʋ
Encapsulated antenna with PTFE
cover, Flange DN 80 … DN 150,
ASME 3" … 6"
10°
Torque for NPT cable glands and Conduit tubes
Ʋ
Plastic housing
max. 10 Nm (7.376 lbf ft)
Ʋ
Aluminium/Stainless steel housing
max. 50 Nm (36.88 lbf ft)
Output variable
Output
Relay output (DPDT), 2 floating spdts
Switching voltage
max. 253 V AC, 253 V DC
Switching current
max. 5 A AC, 1 A DC
Breaking capacity
Ʋ
Min.
50 mW
Ʋ
Max.
750 VA AC (cos phi > 0.5), 40 W DC (ohmic load)
If inductive loads or stronger currents are switched
through, the gold plating on the relay contact surface will
be permanently damaged. The contact is then no longer
suitable for switching low-level signal circuits.
Contact material (relay contacts)
AgNi (Au plated) or AgSnO (Au plated)
Modes (switchable)
Ʋ
max.
Max. detection or overflow/overfill protection
Ʋ
min.
Min. detection or dry run protection
1)
Outside the specified beam angle, the energy of the radar signal has a level of -3 dB (50 %).