12
3 Product description
VEGAPULS SR 68 • 4 … 20 mA/HART two-wire
38294-EN-130624
Up to the time of installation, the packages must be left closed and
stored according to the orientation and storage markings on the
outside.
Unless otherwise indicated, the packages must be stored only under
the following conditions:
•
Not in the open
•
Dry and dust free
•
Not exposed to corrosive media
•
Protected against solar radiation
•
Avoiding mechanical shock and vibration
•
Storage and transport temperature see chapter "
Supplement -
Technical data - Ambient conditions
"
•
Relative humidity 20 … 85 %
3.4 Accessories and replacement parts
The display and adjustment module PLICSCOM is used for measured
value indication, adjustment and diagnosis. It can be inserted into the
sensor or the external display and adjustment unit and removed at
any time.
You can find further information in the operating instructions "
Display
and adjustment module PLICSCOM
" (Document-ID 27835).
The interface adapter VEGACONNECT enables the connection of
communication-capable instruments to the USB interface of a PC. For
parameter adjustment of these instruments, the adjustment software
PACTware with VEGA-DTM is required.
You can find further information in the operating instructions "
Interface
adapter VEGACONNECT
" (Document-ID 32628).
The VEGADIS 81 is an external display and adjustment unit for VEGA
plics
®
sensors.
For sensors with double chamber housing the interface adapter
"
DISADAPT
" is also required for VEGADIS 81.
You can find further information in the operating instructions "
VE-
GADIS 81
" (Document-ID 43814).
VEGADIS 62 is suitable for measured value indication and adjustment
of sensors with HART protocol. It is looped into the 4 … 20 mA/HART
signal cable.
You can find further information in the operating instructions "
VE-
GADIS 62
" (Document-ID 36469).
The PLICSMOBILE T61 is an external GSM/GPRS radio unit for
transmission of measured values and for remote parameter adjust-
ment of plics
®
sensors. The adjustment is carried out via PACTware/
DTM by using the integrated USB connection.
You can find further information in the supplementary instructions
"
PLICSMOBILE T61
" (Document-ID 37700).
Storage
Storage and transport
temperature
PLICSCOM
VEGACONNECT
VEGADIS 81
VEGADIS 62
PLICSMOBILE T61