5
.
5
W
iring plan
,
version
IP
66
/
IP
68
,
1
bar
+
-
1
2
F
ig
.
23
:
W
ire assignment
,
connection cable
1
brown
(
+
)
and blue
(-)
to power supply or to the processing system
2
S
creen
5
.
6
S
witch
-
on phase
A
fter connecting
VEGASON
63
to power supply or after a
voltage recurrence
,
the instruments carries out a self
-
check for
approx
.
30
seconds
:
l
I
nternal check of the electronics
l
I
ndication of the instrument type
,
the
fi
rmware as well as
the sensor
TAG
s
(
sensor designation
)
l
O
utput signal jumps brie
fl
y
(
approx
.
10
seconds
)
to the set
fault current
T
hen the corresponding current is outputted to the cable
(
the
value corresponds to the actual level as well as the settings
already carried out
,
e
.
g
.
factory setting
).
W
ire assignment
,
connection
cable
S
witch
-
on phase
VEGASON
63
-
4
...
20
m
A
/
HART
27
C
onnecting to power supply
28777
-
EN
-
070507