41
9 Supplement
VEGASWING 63 • Two-wire 8/16 mA
29232-EN-180704
Electromechanical data - version IP 66/IP 68 (1 bar)
Cable entry
Ʋ Single chamber housing
– 1 x IP 68 cable gland M20 x 1.5; 1 x blind plug
M20 x 1.5
or:
– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT
Connection cable
Ʋ Wire cross-section
> 0.5 mm² (AWG 20)
Ʋ Wire resistance
< 0.036 Ω/m (0.011 Ω/ft)
Ʋ Tensile strength
< 1200 N (270 lbf)
Ʋ Standard length
5 m (16.4 ft)
Ʋ Max. length
1000 m (3280 ft)
Ʋ Min. bending radius
25 mm (0.984 in) with 25 °C (77 °F)
Ʋ Diameter approx.
8 mm (0.315 in)
Ʋ Colour - standard PE
Black
Ʋ Colour - standard PUR
Blue
Ʋ Colour - Ex-version
Blue
Adjustment elements
Sensitivity switch
Ʋ ≥ 0.5 g/cm³
0.5 … 2.5 g/cm³ (0.018 … 0.09 lbs/in³)
Ʋ ≥ 0.7 g/cm³
0.7 … 2.5 g/cm³ (0.025 … 0.09 lbs/in³)
Voltage supply
Operating voltage (via the signal conditioning instrument)
Ʋ Non-Ex instrument
12 … 36 V DC
Ʋ Ex-d instrument (ATEX, FM, CSA)
12 … 36 V DC
Ʋ Ex-ia instrument (ATEX)
12 … 29 V DC
Ʋ Ex-ia instrument (FM, CSA)
12 … 31 V DC
Electrical protective measures
Protection rating
Ʋ Plastic housing
IP 66/IP 67 (NEMA Type 4X)
Ʋ Aluminium and stainless steel (stand-
ard)
IP 66/IP 68 (0.2 bar), NEMA Type 6P
3)
Ʋ Aluminium and stainless housing
(optionally available)
IP 66/IP 68 (1 bar), NEMA Type 6P
Protection class
II
Functional safety (SIL)
Functional safety according to IEC 61508/IEC 61511
Ʋ Single channel architecture (1oo1D) up to SIL2
3)
A suitable cable is required for maintaining the protection rating.