S p e c i f i c a t i o n s
Measurement limits
General specifications
Electrical specifications
Standard & Optional Accessories
Standard
Soft carrying case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AC259
Test leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ATL55
Optional
Plug-in line splitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ASL1
Temperature measurement adapter . . . . . . . . . . . . . . . . . . . . . .TA2K
Hard carrying case (service kits) . . . . . . . . . . . . . . . . . . . . . . . . .AC506
High voltage probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KHV66
Flame safeguard test adapter . . . . . . . . . . . . . . . . . . . . . . . . . . .DLMAT
Frequency
AC Amperage
DC Amperage
AC Voltage
DC Voltage
Ohms
Continuity
50 - 400 Hz
400 Amps
400 Amps
600 Volts
600 Volts
40 Megohms
<50 ohms
Size (H x W x L)
Operating temperature
Storage temperature
Relative humidity
(storage and use)
Weight
Calibration frequency
Ul listing
IEC Listing
Battery
Battery life
7.68” x 3.06” x 1.79”
(195 x 77 x 46 mm)
32 to 113˚F (0 to 45˚C)
-4 to 140˚F (-20 to 60˚C)
0% to 80% RH
13 oz. (370g)
Annual
3111-1
1010-1 (CAT III 600 Volts)
9V Alkaline (NEDA 1604
or 6F22 or 006P)
80 hours typical (Alkaline)
Function
Ohms (
Ω
)
Volts AC
(50-400 Hz)
Volts DC
Amps AC
(50-400 Hz)
Amps DC
Range
400
Ω
4 K
Ω
40 K
Ω
400 K
Ω
4 MΩ
40 M
Ω
4 V
40 V
400 V
600 V
4V
40 V
400 V
600 V
40 A
400 A
40 A
400 A
Resolution
0.1
Ω
1.0
Ω
10
Ω
100
Ω
1 K
Ω
10 K
Ω
1 mV
10 mV
100 mV
1 V
1 mV
10 mV
100 mV
1 V
0.01 A
0.1 A
0.01 A
0.1 A
Accuracy
±(0.9% + 3 digits)
±(1.2% + 5 digits)
±(1.5% + 3 digits)
±(0.9% + 2 digits)
±(2% + 5 digits)
±(3% + 10 digits)
±(2.5% + 10 digits)
±(1.5% + 5 digits)