AC80T Tower Crane Purpose VFD Manual
22
F3.21
Reserve
〇
F3.22
A01 output selection
0: Given frequency
1: Output frequency
2: Output current
3: Input voltage
4: Output voltage
5: Mechanical speed
6: Reserve
7: Output torque
8: PID given volume
9: PID feedback volume
10: Output power
11: Bus voltage
12: VS1 input value
13: VS2 input value
14:AS input value
15: PUL input value
16: Module temperature 1
17: Module temperature 2
0
●
F3.23 A02
intput
selection
1
●
F3.24 A01
input
gain
25.0
~
200.0% 100.0%
●
F3.25
A01 output signal bias
-10.0
~
10.0% 0.0%
●
F3.26
A02 singal seclection
0: 0
~
10V
1: 4.00
~
20.00mA
2: 0.00
~
20.00mA
3: FM frequency pulse
output
0
●
F3.27 A02
input
gain
25.0
~
200.0% 100.0%
●
F3.28
A02 simulationoutput
signal bias
-10.0%
~
10.0%
0.0%
●
F3.29
A02FM frequency output
lower limit
0.00
~
50.00kHz 0.20kHz
●
F3.30
A02FM frequency output
upper limit
0.00
~
50.00kHz 50.00kHz
●
Keyboard and display parameter set
No.
Function description
Range of setting and
definition
Factory
default
Pr
op
ert
y
Com
muni
catio
n
add.
F4.11
The display content of
the first line at the
running state
LED “0” digit: display the first
group
0: Given frequency
1: Output frequency
2: Output current
3: Input voltage
4: Output voltage
5: Mechanical speed
6: Reserve
7: Output torque
8: PID given volume
9: PID feedback volume
A: Output power
B: DC bus voltage
3210
●