16
Pn047
Torque limit release time
when the main circuit voltage
drops
0~1000
100
ms
0x0047
INST
After the under voltage warning release signal, the servo unit internally controls the torque limit
value according to the set time. For details, see the description of "Main Circuit Under voltage
Torque Limit"
Pn050
Torque limit mode setting
0~3
1
-
0x0050
INST
0 –Analog torque
(
invalid torque mode
)
1 -Maximum torque limit 1
2 -Forward torque limit 1; Reverse torque limit 2
3 -Maximum torque limit 1 when the switching value "torque limit switching" is OFF; maximum
torque limit 2 when it is ON
Pn051
Maximum torque limit 1
0~500
500
%
0x005
1
INST
Pn052
Maximum torque limit 2
0~500
500
%
0x0052
INST
Pn053
Emergency stop torque
0~800
800
%
0x0053
INST
Pn061
Panel parameter display
selection
0x00~0x01
1
-
0x0061
RST
0- Only display setting parameters 1- Show all parameters
Pn070
Encoder frequency division
pulse number
16~4194304
2048
-
0x0070
RST
According to the setting value of this parameter, the frequency of pulses from the encoder per
revolution is divided, please set according to the system specifications of the machine and the host
device
Pn072
Inverted crossover output
0~1
0
-
0x0072
RST
0- Pulse output is not inverted
:
When forward, A leads B 1- Pulse output reversed: when
forward, B leads A
Pn080
Local communication
address
0x00~0x7F
1
-
0x0080
RST
Pn081
485 communication baud rate
selection
0~4
1
-
0x0081
RST
0-9600bps 1-19200bps 2-38400bps 3-57600bps 4-115200bps
Pn082
485 Communication
verification method
0~5
1
-
0x0082
RST
0- No check (N,8,1) 1- Even parity (E,8,1) 2- Odd parity (O,8,1) 3- No check (N,8,2)
4- Even parity (E,8,2) 5-Odd parity (O,8,2)