32
3.6
Pn5 JOG Related Parameters
Function
code
Parameters
Range
Default
Unit
Address
Effective
way
Pn500
JOG speed
0~1000
500
rpm
0x0500
INST
Pn502
Program JOG running
mode
0x00~0x05
0
-
0x0502
INST
0- (wait time-> forward movement) * number of cycles
1- (wait time-> reverse movement) * number of cycles
2- (wait time-> forward movement) * number of cycles-> (wait time-> reverse movement) *
number of cycles
3- (waiting time-> reverse movement) * number of cycles-> (waiting time-> forward movement)
* number of cycles
4- (wait time-> forward movement-> wait time-> reverse movement) * number of cycles
5- (wait time-> reverse movement-> wait time-> forward movement) * number of cycles
Pn503
Program JOG moving
distance
1~107374182
4
32768
Command
unit
0x0503
INST
Set the running distance of the running program JOG as the command unit
Pn505
Program JOG
acceleration/deceleration
time
2~10000
100
ms
0x0505
INST
The time required to accelerate the set speed from 0r / min to the rated speed (corresponding to the
motor model)
Pn506
Program JOG waiting time
0~10000
100
ms
0x0506
INST
Set the waiting time between the JOG segments of the running program, in conjunction with the
program JOG running mode (Pn502)
Pn507
Program JOG moving times
0~1000
1
回
0x0507
INST
Set the number of JOG movements of the running program, in conjunction with the running mode
of the program JOG (Pn502)
Pn508
Program JOG moving
speed
1~10000
500
rpm
0x0508
INST
Summary of Contents for SD700-110D series
Page 8: ...4 ...
Page 14: ...10 1 10 Position Control Wiring Diagram ...
Page 15: ...11 1 11 Speed Control Wiring Diagram ...