SI21 Solar Pump VFD Manual
33
F21.25(0x5519)
Minimum power
protection auto
restore working
time
0.0s
~
3000.0s
10.0s
F21.26(0x551A)
Fault alarm restore
mode
0:Auto reset;1:Reset by manual
LED0:Low speed protection
LED1:Dry run
LED2:Over current protection
LED3: Minimum power protection
0000
F21.27(0x551B)
Water fulfilled
detect time
0.0s
~
3000.0s
10.0s
F21.28(0x551C)
Water fulfilled
restore time
0.0s
~
3000.0s
10.0s
F21.29(0x551D)
reserve
F21.30(0x551E)
DC current revise
offset
0.00A
~
99.99A
0.01A
F21.31(0x551F)
DC current revise
proportion gain
0.0%
~
999.9%
100.0%
F21.32(0x5520)
Power curve point 0
0.00kW
~
99.99kW
0.50kW
F21.33(0x5521)
Power curve point 1
0.00kW
~
99.99kW
1.00kW
F21.34(0x5522)
Power curve point 2
0.00kW
~
99.99kW
1.50kW
F21.35(0x5523)
Power curve point 3
0.00kW
~
99.99kW
2.00kW
F21.36(0x5524)
Power curve point 4
0.00kW
~
99.99kW
2.50kW
F21.37(0x5525)
Flow curve point 0
0.0m³
/h
~
999.9m³
/h
0.0m³
/h
F21.38(0x5526)
Flow curve point 1
0.0m³
/h
~
999.9m³
/h
5.0m³
/h
F21.39(0x5527)
Flow curve point 2
0.0m³
/h
~
999.9m³
/h
10.0m³
/h
F21.40(0x5528)
Flow curve point 3
0.0m³
/h
~
999.9m³
/h
15.0m³
/h
F21.41(0x5529)
Flow curve point 4
0.0m³
/h
~
999.9m³
/h
20.0m³
/h
F21.42(0x552A)
Flow calculating
revise offset
0.0m³
~
999.9m³
0.0m³
F21.43(0x552B)
Flow calculating
revise gain
0.0%
~
999.9%
100.0%
F21.44(0x552C)
Power per day/
generated power
per day reset period
0.0h
~
24.0h
7.0h
F21.45(0x552D)
Reserved