background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

   

 

   

   

 

 

 

 

 

 

Model: 

 

Ingress Protection 

Level: 

IP68(1.2m/45min) 

Ex marking: 

2460

 

II

2G Ex db 

II

C T6 Gb 

II

2D Ex tb 

III

C T80 ºC Db 

Camera type 

HD network/Analog 

         

by 

 

China 

 

National 

 

Quality 

 

Supervision 

 

and 

 

Test 

 

Center 

 

for 

 

Explosion 

 

Protected 

 

Electrical

All associate technical document, drawings and samples of

 

the camera

 

are tested and certified

 

industry,

 

aircraft industry, military industry,

 

food

 

processing

 

industry and so on.

It’s applicable for

 

petrol industry, chemical industry, wharf,

 

harbor,

 

non-coal

 

mine,

 

aerospace

 

2013. The

 

compact structure, small size make it convenient for installation and maintenance.

 

EN60079-1:  2014,

 

EN60079-31:  2014,

 

IEC60079-0:  2011,

 

IEC60079-1:  2014,

 

IEC60079-31:

The 

 

camera 

 

is 

 

designed 

 

and 

 

manufactured 

 

according 

 

to 

 

EN60079-0:2012+A11: 

 

2013,

 

purpose of monitoring the hazardous area.

be 

 

used 

 

in 

 

flammable 

 

and 

 

explosive 

 

gas 

 

or 

 

flammable 

 

dust 

 

environment, 

 

to 

 

achieve 

 

the

 

guarantee, the quality, performance and appearance are in leading position. The product can

 

adopts 

 

advanced 

 

manufacturing 

 

process, 

 

with 

 

 

mature 

 

quality 

 

management 

 

system 

 

as 

 

a

 

(hereinafter

 

referred

 

to

 

as camera) is a new generation of

 

Explosion-proof

 

monitoring device, it

 

SVEX-T100   

     

WITH 

 

WIPER

 

Explosion-proof

 

Camera

 

1.

 

General

 

  

SVEX-T100

 

Without

 

Wiper

 

/

 

SVEX-T300

 

With

 

Wiper

 

Explosion-proof

 

Camera

·

Instruction

 

Manual

WITHOUT

 

WIPER

 

/

 

SVEX-T300

Model

SVEX-T300A,

 

SVEX-T300.

  

Company code

(100

 

no wiper;

 

300

 

w/wiper)

Product code

:

 

B

S

 

V

 

E

 

X

 

-

 

T

 

1

 

0

 

0

 

B

1.1.

 

Specification

Apparatus (CQST),

 

ATEX certification number:

 

2460

 

Presafe

 

17

 

ATEX

 

11326X.

SVEX-T300

 

WITH WIPER

SVEX-T100

 

WITHOUT WIPER /

Summary of Contents for SVEX-T100

Page 1: ... before use 2460 Ⅱ2G Ex db ⅡC T6 Gb Ⅱ2D Ex tb ⅢC T80ºC Db EN60079 0 2012 A11 2013 EN60079 1 2014 EN60079 31 2014 IEC60079 0 2011 IEC60079 1 2014 IEC60079 31 2013 Ex marking Reference standards Instruction Manual Explosion proof Camera SVEX T300 with Wiper SVEX T100 without Wiper ...

Page 2: ...on Manual carefully before installation and operation of this product following the instructions and keep this instruction manual properly Copyright 2017 VEILUX INC All right reserved SVEX T100 Without Wiper SVEX T300 With Wiper Explosion proof Camera Instruction Manual ...

Page 3: ...SVEX T300 With Wiper Explosion proof Camera Instruction Manual guarantee period but we will ask the user to pay for the cost of labor Explosion proof Camera we provide free maintain service in the For SVEX T100 WITHOUT WIPER SVEX T300 WITH WIPER Quality Guarantee www veilux net The end users can get the latest product information on our website form of notification to provide the newest and most a...

Page 4: ...cated in the nameplate To be sure the power supply complies with the requirement humidity specified in Chapter 1 6 atmosphere pressure ambient temperature and relative Ensure this product is always used in environment with requirements in this Instruction Manual or seepage Please operate the product according to the as removal of top cover or bolts may cause leakage of water SVEX T100 Without Wipe...

Page 5: ... disassembly or modification allowed 2 Construction Safety The protective regulations on construction spot shall be followed strictly Measurement shall be carried out immediately when any security risks found to eliminate the risks stop construction if necessary All kinds of safety facilities shall be inspected calibrated or repaired in the event of severe weather The ice fog rain and snow shall b...

Page 6: ...external grounding shall be reliable and the We suggest using this product with Lightning Protection Devices in transmission The product shall be well packaged as new product or equivalent transmission storage or operation Avoid damage caused by compressing or violent vibration in Avoid overheated the product shall be well ventilated element conductive fluid which may damage the internal electrica...

Page 7: ...hen the product updates there may exist specifications of the product in this Instruction Manual without any We remain the right to modify the content and technical Pictures in this manual is a diagram for reference only Special announcement environment no casually discard allowed avoid any adversative effect to the sources shall be delivered to the government for further treatment in maintenance ...

Page 8: ...re The enclosure is able to subject to static pressure test 1 8MPa for at least 10s specified in EN60079 01 2014 IEC60079 1 2014 no leakage or deformation allowed after test The maximum surface temperature will no more than 80ºC in normal operation Tempering glass is adopted in observation port the tempering glass shall pass the impact and thermal shock test Ingress protection level IP68 1 2m 45mi...

Page 9: ...art of the camera housing do not hold from the sunshade wiper or wiper base do not drag or toss When the product is POWERED DO NOT open move knock or drag this product SVEX T100 Without Wiper SVEX T300 With Wiper Explosion proof Camera Instruction Manual ...

Page 10: ...ng and operation 8 2 4 1 Instruction for installation 7 2 4 On spot installation and fixing 7 2 3 1 Support installation 5 2 3 Preparation of supports before installation 5 2 2 Cable entry 5 2 1 Cautions before installation 4 2 Installation debugging 4 1 8 Special conditions for safe use 4 1 7 Electrical safety in normal atmosphere 3 1 6 Service condition 3 1 5 Electrical parameters 3 1 4 Mechanic...

Page 11: ...31 The camera is designed and manufactured according to EN60079 0 2012 A11 2013 purpose of monitoring the hazardous area be used in flammable and explosive gas or flammable dust environment to achieve the guarantee the quality performance and appearance are in leading position The product can adopts advanced manufacturing process with a mature quality management system as a hereinafter referred to...

Page 12: ... camera The surge protection device provided with the camera will make it This camera can work at wide voltage range and its self adaptation function will satisfy most role in security systems This camera integrated a variety of communication protocols and speed it plays an important 1 2 Characters 2 SVEX T100 SVEX T100 Without Wiper SVEX T300 With Wiper Explosion proof Camera Instruction Manual S...

Page 13: ...al 2 way alarm input 1 way alarm output Address code 0 1 1 6 Service condition Atmosphere pressure 80 110kPa Ambient temperature 40ºC 60ºC Relative humidity no more than 95 25ºC 1 7 Electrical safety in normal atmosphere Insulation resistance the insulation resistance between power terminal and the enclosure shall be no less than 50 MΩ SVEX T100 Without Wiper SVEX T300 With Wiper Explosion proof C...

Page 14: ...l with ATEX cert 1pcs for each 4 Stopping plugs 2pcs 3 M6 inner hexagon spanner 1pcs 2 SVEX T100A or SVEX T100B main set 1pcs SVEX T100 1 Accessories in packaged product 2 1 Cautions before installation Installation debugging 2 Ambient temperature 40ºC 60ºC Yield stress of the flameproof enclosure fasteners shall be no less than 450MPa Width of the flameproof joints are greater than values specifi...

Page 15: ...ay affect the fasteners comply with associate load and anti rust requirements Installation of the camera It s the user s responsibility to ensure the support for the camera is strong enough and the significantly We strongly suggest you select supports from VEILUX it will ease your installation process The debugging is done before package only installation in the intended location is required 2 3 P...

Page 16: ...Installation of support Figure 2 3 1 2 Dimension of support Figure 2 3 1 3 Front view of support Figure 2 3 1 4 Side view of support SVEX T100 Without Wiper SVEX T300 With Wiper Explosion proof Camera Instruction Manual ...

Page 17: ... reserved cable of the camera through the cable in the support the cable See Figure 2 3 1 2 for distribution of installations holes under the camera take SVEX T300A 2 4 1 Instruction for installation locations if available Since Ex product is very special adjust with power indoors before installation in the intended 2 4 On spot installation and fixing SVEX T100 Without Wiper SVEX T300 With Wiper E...

Page 18: ...al video signal transmission it s available for users to monitor or record the videos at any time by network no matter in local area network LAN or wide area network WAN such as internet 2 5 1 System connection 2 5 Adjusting and operation SVEX T100 Without Wiper SVEX T300 With Wiper Explosion proof Camera Instruction Manual ...

Page 19: ... address Set according to instruction manual of camera Incorrect protocol Incorrect baud rate Uncontrolled camera Incorrect model of camera Incorrect setting of control model SW1 3 Trouble shooting setting See camera manufacturer s instruction manual for camera IE browser and client software 2 5 4 Settings of camera IE browser and client software The camera will start self checking automatically a...

Page 20: ...rs after putting into service the rubber sealing ring need to be replaced if cables will not affect other objects during rotation Inspect the cables ensure the protective sheath are not damaged and the 2 Check all the fasteners 1 Six months after putting into service 4 3 Maintenance obvious vibration temperature range 0ºC 40 ºC and humidity no more than 90 This product can be stored for one year i...

Page 21: ... the limit specified in the standard SJ T11363 2006 Leakage or mutation of this poisonous harmful substances or elements will not happen in the environmental life and will not harm the user s health or properties Treatment of this poisonous harmful substances or elements cannot carried out by user selves please deliver it to the appointed department according to the local laws or regulations or di...

Page 22: ...12 802 Greenview Dr Ste 200 Grand Prairie TX 75050 USA TEL 1 800 510 6528 Website www veilux net SVEX T100 Without Wiper SVEX T300 With Wiper Explosion proof Camera Instruction Manual ...

Reviews: