Veilux VR - 412D1 & VR - 412C Compact DVR’s
www.veilux.net
15
Operating Instruction & User’s Guide
(1) Sensor Connection
①
Connect Sensor to VR -412D1
Terminal Block S1 ~ S4 to GND
.
②
Each input terminal may be connected regardless of the channel number
.
Sensor types include Normal Close (NC) and Normal Open (NO). For more
information on setup by sensor type, refer to
{Menu}
{Setup}
{Recording}
{Event}
{Sensor} .
NC(Normal Close)
: Normally closed; opens when a signal is received
.
NO(Normal Open)
: Normally open; closes when a signal is received
.
(2) Relay Connection
①
Outputs alarm signals to external devices such as LED and siren by relaying them to these external
devices .
②
Connect Relay to R1_NC or R1_NO and R1_COM
.
Relay types include Normal Close (NC) and Normal Open (NO)
.
NC (Normal Close)
: Normally closed; open s when a signal is received
.
NO (Normal Open)
: Normally open; closes when a signal is received
.
3.
Operation and Setup Tools
VR -412C
is operated by Front Button, Remote Controller and Mouse
.
3-
1
VR -412C Front Button
No.
Name
Feature
1
POWER LED
System pow er ON or OFF LED
2
HDD LED
HDD in operation; Green Light
3
PTZ
PTZ Menu and Pan Tilt Zoom Mode Change (Only
VR -
412D1
supported )
4
FULL
Full Screen
5
QUAD
Quad Screen
6
REW
Play backward / Rewind (In playback mode )
7
PLAY
Play forward / Fast Forward (In playback mode )
8
SEQ/FRAME
Auto -Sequence
/ Playback frame by frame (In playback
®