VEIMART INSTALLATION GUIDE

The insulation casing is opened and closed with metallic clips. The 
insulation casing prevents condensation caused by the cold water. If 
there is no room, the insulation casing can be left off.

Turn the bypass valve as shown in the picture so the water runs through 
the water guard. In case of an electrical failure it is possible to get water 
if the bypass valve is turned in the same direction as the water pipe. It 
might also be necessary to bypass the water guard if it requires constant 
resets and professional help is not available immediately.

WHAT TO DO IMMEDIATELY AFTER INSTALLATION: 

Since there might be air in the plumbing that can disturb the operation of 

the water guard, make sure to run water from all taps long enough for all air to be expelled. Don’t forget any water taps you 
might have outside.

115

AWAY

RESET

HOME

2 m

240

200

160

VMEX-10

VMSW-S

(surface installation)

VM-10 BASIC PACKAGE

ACCESSORIES

Leakage sensors can be placed in critical 
positions, such as below washing machines and 
manifolds, to detect leaks (this way the system 
can also detect any leaks in sewer connections). 
Any alarm caused by the leakage sensor must 
be resetted before the Veimart unit reopens the 
valve.

VMSW-S is a surface installed, two-part switch 
that has one button for resetting alarms (spring 
return) and another one for the Away function. 
Can be installed e.g. close to a door in the hall.

WARRANTY: 

The warranty only covers 

repairing the device or delivering a new 
device to replace a faulty one. The warranty 
does not cover any direct or indirect 
damage the device may cause to the 
customer or the user, nor is the supplier of 
the device responsible for such damage.

OR

REMOTE CONTROL OF 
AWAY MODE 
(e.g. through a home 
automation system)

ALARM INFORMATION

AWAY - STATUS 
INFORMATION

VMLS-10

(Cabling of field devices: 

e.g. KLM 4 x 0.8)

SPECIFICATIONS

WATER GUARD

Product code, 

VM-10

WATER GUARD BODY

Material 

Brass that can resist 

 

dezincification CB772S

Space needed for installation 

160 mm

Input terminal 

3/4” male thread with gasket

Output terminal 

22 mm compression coupling

Weight 

2.75 kg

Dimensions 

240 x 200 x 115 (with insulation 

 

protection), installation direction 

 

can be chosen freely

CONTROL UNIT

 

Width x height x depth 

130 x 90 x 38

Operating voltage  

24 VDC

Connecting cable 

2 m, plug-in connection

ACCESSORIES

  

Product code   

Extension cable for the control unit 5 m 

VMC-5 

Extension cable for the control unit 10 m 

VMC-10 

Extension cable for the control unit 20 m 

VMC-20 

Extension unit 

 

VMEX-10 

Leakage sensor 

 

VMLS-10 

Switch (surface installation) 

 

VMSW-S 

Water meter connector  
(incl. one-way valve) 

 

VM-3/4UKx1SK 

  

Country of manufacture 

Finland

Warranty 

2 years

APPROVALS

 

EN-55022, LVD

Attaching the control unit to a wall. The mounting screw holes are hid-
den behind the covers. If necessary, the control unit can be moved fur-
ther away from the water guard using an extension cable.

The Veimart system is installed immediately after the water meter and 
the check valve. A possible pressure relief valve is usually installed af-
ter the Veimart device. If there is not a lot of space for installation, it is 
recommended to a use a water meter coupling with a one-way valve, 
VM-3/4UKx1SK (accessory).

VM-3/4UKX1SK

2 m

2 m