VEIMART INSTALLATION GUIDE
The insulation casing is opened and closed with metallic clips. The
insulation casing prevents condensation caused by the cold water. If
there is no room, the insulation casing can be left off.
Turn the bypass valve as shown in the picture so the water runs through
the water guard. In case of an electrical failure it is possible to get water
if the bypass valve is turned in the same direction as the water pipe. It
might also be necessary to bypass the water guard if it requires constant
resets and professional help is not available immediately.
WHAT TO DO IMMEDIATELY AFTER INSTALLATION:
Since there might be air in the plumbing that can disturb the operation of
the water guard, make sure to run water from all taps long enough for all air to be expelled. Don’t forget any water taps you
might have outside.
115
AWAY
RESET
HOME
2 m
240
200
160
VMEX-10
VMSW-S
(surface installation)
VM-10 BASIC PACKAGE
ACCESSORIES
Leakage sensors can be placed in critical
positions, such as below washing machines and
manifolds, to detect leaks (this way the system
can also detect any leaks in sewer connections).
Any alarm caused by the leakage sensor must
be resetted before the Veimart unit reopens the
valve.
VMSW-S is a surface installed, two-part switch
that has one button for resetting alarms (spring
return) and another one for the Away function.
Can be installed e.g. close to a door in the hall.
WARRANTY:
The warranty only covers
repairing the device or delivering a new
device to replace a faulty one. The warranty
does not cover any direct or indirect
damage the device may cause to the
customer or the user, nor is the supplier of
the device responsible for such damage.
OR
REMOTE CONTROL OF
AWAY MODE
(e.g. through a home
automation system)
ALARM INFORMATION
AWAY - STATUS
INFORMATION
VMLS-10
(Cabling of field devices:
e.g. KLM 4 x 0.8)
SPECIFICATIONS
WATER GUARD
Product code,
VM-10
WATER GUARD BODY
Material
Brass that can resist
dezincification CB772S
Space needed for installation
160 mm
Input terminal
3/4” male thread with gasket
Output terminal
22 mm compression coupling
Weight
2.75 kg
Dimensions
240 x 200 x 115 (with insulation
protection), installation direction
can be chosen freely
CONTROL UNIT
Width x height x depth
130 x 90 x 38
Operating voltage
24 VDC
Connecting cable
2 m, plug-in connection
ACCESSORIES
Product code
Extension cable for the control unit 5 m
VMC-5
Extension cable for the control unit 10 m
VMC-10
Extension cable for the control unit 20 m
VMC-20
Extension unit
VMEX-10
Leakage sensor
VMLS-10
Switch (surface installation)
VMSW-S
Water meter connector
(incl. one-way valve)
VM-3/4UKx1SK
Country of manufacture
Finland
Warranty
2 years
APPROVALS
EN-55022, LVD
Attaching the control unit to a wall. The mounting screw holes are hid-
den behind the covers. If necessary, the control unit can be moved fur-
ther away from the water guard using an extension cable.
The Veimart system is installed immediately after the water meter and
the check valve. A possible pressure relief valve is usually installed af-
ter the Veimart device. If there is not a lot of space for installation, it is
recommended to a use a water meter coupling with a one-way valve,
VM-3/4UKx1SK (accessory).
VM-3/4UKX1SK
2 m
2 m