Page 1: ...Handbook BX 1000 BX 600 Pressing for Excellence GB ...

Page 2: ...system with continuous upper and lower belts a cooling station with long life polyester belt a control unit for easy operation and reading Long life maintenance free elements and good insulation reduce operating costs and energy consumption to a minimum With the Fuse master BX series 2 different pressure systems are available If necessary the pressure system can be changed even at a later date Thi...

Page 3: ...ature and pressure and fusing time thanks to the clearly marked symbols The set and actual working temperatures are digitally indicated and easily read Control elements G1 adjustment of the fusing time N1 adjustment of the upper temperature N2 adjustment of the lower temperature D1 adjustment of the pressure S0 key stop S1 key start H1 slight lack of compressed air H2 slight disturbance in the dri...

Page 4: ...nded 2 Clean the belts with the cleaning cloth 3 Turn the wiper bar with a clean surface facing the belt 4 Clean the delivery rail to the cooling belt and the stripping rail with a soft cloth 5 Drain the sediment bowl of the air cleaner if necessary 6 Switch off the main switches of the machine Approx 20 minutes after switching off the heating 7 Pull the cleaning cloth out of the machine Maintenan...

Page 5: ...harp tools for cleaning This shortens the belt life Covers or towels of cleaning bars or cleaning devices should regularly be checked or replaced Transfer and strip off blades should be cleaned in regular intervals from resin and dust build up The machine must be cleaned before shut down resins hardened over night damage the belts when production starts the next day Tracking and tension of the bel...

Page 6: ...e cleaning agent KANFIX is not only suitable for cleaning the Teflon coated belts It also conserves the belts as an additional coating on the belts to avoid agglomeration of glue residues The cleaning agent KANFIX is non toxic solvent free and silicone free Use KANFIX only once a day Spread it on an approx 10 cm wide strip of the cotton molton fabric and insert it into the machine ...

Page 7: ...clean between the belts The cleaning cloth should be used as often as possible i e during every break mornings lunchtime etc and at the end of the day Do not leave the cleaning cloth in the machine overnight as the dirty cloth sticks to the belts after they have cooled down The belts are then damaged when the machine is restarted After cleaning two people should pull the cloth out of the machine a...

Page 8: ...KANFIX KANfix contains no silicon Silicone containing cleaning agents cause damages to the belts the heating elements and the rubber coated rollers KANfix 250g container Art Nr 214 607 4 KANfix box with 12 x 250g containers Art Nr 214 608 2 ...

Page 9: ... ors are located in this area The required fusing time can be set on the speed metre When the article is in the machine the upper heating zone warms up the material The required temperature is set on the thermostat The articles are transported between the seamless belts towards the main heating zone Here the lower heating zone applies heat to the articles The desired temperature can be set on the ...

Page 10: ...ry The heating system of the Fuse Master BX The heating surface consists of a series of metal profiles that form a curved panel Heating circuits are laminated directly onto the inside of the contact surface of each heating profile The sensors of the thermostats are positioned in the heating profiles close to the heating mat and the profile surface This integration guarantees even heat across the e...

Page 11: ...e kind of material as well as the kind of interlining Therefore we recommend exactly following the fusing recommendations of the interlining manufacturers and always carrying out preliminary tests The Fuse Master BX pressure system variations With the Fuse Master BX concept Kannegiesser offers the possibility of selecting two different pressure systems O Pressure system for outerwear fusing S Pres...

Page 12: ...ecisely adjustable by means of pneumatic cylinders A sturdy pressure rocker provides for constant pressure over the entire working width The specific pressure is changed by adjusting the air pressure The limited elasticity of the silicone coating means that the pressure system can only partially react to thickness differences Therefore bonding problems can occur when simultaneously fusing material...

Page 13: ...e kind of interlining or fabric Therefore the interlining manufacturers indicate the required bond strength per interlining Appearance of adhesion test After fusing fabric and interlining are pulled apart The adhesion test gives a special indication With a good bond the coating of the interlining should have been transferred 50 or more to the fabric If this is not the case the bond is not sufficie...

Page 14: ...es We recommend covered paper measuring tapes in order to minimize the influence of humidity of the fabric These paper measuring tapes can be ordered from Kannegiesser Garment Textile Technologies GmbH Co temperature ranges 104 C 143 C order Nr 046 053 5 and 143 C 182 C order Nr 046 054 3 The measured temperature between the belts without fusing material at medium machine speed should be in accord...

Page 15: ...dness Furthermore the pressure roller should be checked for faults and contractions which can be caused by aggressive cleaning agents Fusing without problems One of the specific characteristics of garment fusing is that the real quality of the process only becomes apparent long after production which means during wearing or finally during dry cleaning or washing Therefore for quality fusing it is ...

Page 16: ... ff fe ec ct t M Mo oi ir re ee e E Ef ff fe ec ct t P Pl le ea at ts s M Mo ov ve e o of f I In nt te er rl li in ni in ng g R Re es si in n S So oi il li in ng g P Pr re es ss su ur re e t to oo o h hi ig gh h P Pr re es ss su ur re e T Te em mp pe er ra at tu ur re e t to oo o h hi ig gh h T Te em mp pe er ra at tu ur re e t to oo o h hi ig gh h T Te em mp pe er ra at tu ur re e M Mo oi is st t...

Page 17: ... and actual working temperatures are digitally indicated and easily read Disturbance diagnostics All electrical and mechanical machine functions are permanently controlled by an automatic diagnosis system Possible malfunctions are immediately recognized and indicated on the panel Possible indications of malfunctions red LED s H1 Trouble insufficient air pressure min 5 3 bar H2 Trouble on drive mot...

Page 18: ...g instructions for information regarding spare parts and further technical details Kannegiesser Garment Textile Technologies GmbH Valdorfer Straße 100 Postfach 1612 D 32602 Vlotho Germany Telefon phone 495733 8713 0 Telefax 495733 8713 45 E mail info veit kannegiesser de ...