Legal instructions, conditions regarding electricity and water supply utility
connections shall be complied with. No technical changes can be made in
the device itself nor in the electrical or water connections.
There should be a full pole circuit breaker, whose contact opening is at
least 3 mm, mounted in the installation site.
Instantaneous water heater is a device with protection class
I
and must be
connected with the grounding cable.
Avoid the connections and material that could pose a risk to electrical and
plumbing systems.
This device must be permantently connected to the fixed installation.
Cable cross section must be suitable to the installed power supply.
Grounded plumbing system does not take the place of a grounding
line.
After installation, electrical components must be protected in a way that
can not be contacted.
Keep in mind that the connection might be very hot when the device is
used for a while.
Do not use the device during or in the possibility of frosting. Water should
become completely fluid before use of the device.
Because of the remaining water inside, the dissembled device should be
stored away from the risk of frosting and never be exposed to frost.
Instantaneous water heater should be planted in an area
where there is no risk of freezing.
EN