Control that level control switch is well fitted and no power cord is stuck
between the covers when placing the front cover on the back cover by
looking at the inside of the cover.
Turn the level control switch on if necessary.
Connect with mounting screws after placing the front cover.
Start Up
The first operation to be done in order to prevent damage to the device is to
remove any debris that may be inside the device and fill the device
completely with water before heating elements start to operate by tapping
the hot water. During this process, the '0' position should be used. Turn on
the hot water faucet after opening the inlet water valve and wait until the
regular water flow starts. Laminar flow of water purified from the air and
foreign matter will be provided after about 1 minute. Then, open hot water
tap a few times to compeletely remove all of the air gaps from the system
and the device.
Turn off the hot water faucet before turning on the device's electrical and
make sure that key stage is set to '0' position.
Turn the power to the device on.
You can make the device ready to use by bringing the step switch to the
desired position.
Check the functions of the device by opening the hot water tap, please
explain how the device works by giving users the usage instructions.
If the device does not start to operate because of very low flow rates, check
the water pressure in your installation or get your installation checked by a
qualified technician to see if there is another problem or not.